نتایج جستجو برای: ph electrode

تعداد نتایج: 228520  

Journal: :Journal of Synthetic Organic Chemistry, Japan 1951

Journal: :Nippon kagaku zassi 1953

Journal: :international journal of nano dimension 0
omid ramezani azghandi department of mechanical engineering, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university) mohammad javad maghrebi department of mechanical engineering, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university) ali reza teymourtash department of mechanical engineering, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university)

in this paper, multi-wall carbon nanotubes (mwcnts), gold nanoparticles (gnp) and glucose oxidase (god) was developed for the specific detection of glucose. mwcnts were chemically modified with the h2so4–hno3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (paa) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/n-hy...

Journal: :international journal of environmental research 0
m. behbahani civil and environmental engineering department, amirkabir university of technology (aut), hafez st., tehran, 15875-4413, iran m.r. alavi moghaddam civil and environmental engineering department, amirkabir university of technology (aut), hafez st., tehran, 15875-4413, iran m. arami textile engineering department, amirkabir university of technology (aut), hafez st., tehran, 15875-4413, iran

this study presents a comparison between aluminum and iron plate electrodes on phosphate removal from aqueous solutions by electrocoagulation process. the effectiveness of main operational parameters such as initial ph, initial phosphate concentration and current density were examined. in addition, treated solution and sludge characteristics, energy consumption and electrode mass depletion were...

Journal: :American journal of critical care : an official publication, American Association of Critical-Care Nurses 2015
Charles R Lambert David Varlotta Marjorie Posey Jadie L Heberlein Janice M Shirley

BACKGROUND The RightLevelpH indicator is a new device designed to measure the pH of gastric aspirate obtained via a nasogastric tube while minimizing exposure of the operator. OBJECTIVE To validate the RightLevelpH indicator in vivo and in vitro. METHODS With general anesthesia, 20 patients had placement of a nasogastric tube and a gastric pH electrode catheter after endotracheal intubation...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم پایه 1392

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Journal: :international journal of environmental research 2011
m. behbahani m.r. alavi moghaddam m. arami

this study presents a comparison between aluminum and iron plate electrodes on phosphate removal from aqueous solutions by electrocoagulation process. the effectiveness of main operational parameters such as initial ph, initial phosphate concentration and current density were examined. in addition, treated solution and sludge characteristics, energy consumption and electrode mass depletion w...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

2013

A pH electrode measures hydrogen ion (H+) activity and produces an electrical potential or voltage. The operation of the pH electrode is based on the principle that an electric potential develops when two liquids of different pH come into contact at opposite sides of a thin glass membrane. This was originally discovered in 1906 by Max Cremer [1]. His discovery laid the foundation for Fritz Habe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید