نتایج جستجو برای: polyglycolic acid
تعداد نتایج: 747454 فیلتر نتایج به سال:
Among 2528 patients operated on using pins, rods, bolts, and screws made of polyglycolic acid or polylactic acid, 108 (4.3%) were affected by a clinically significant local inflammatory, sterile tissue reaction. The three most common indications for the use of these fixation devices were a displaced malleolar fracture, a chevron osteotomy for hallux valgus, and a displaced fracture of the radia...
Objectives Anastomotic complications after colorectal surgery are one of the most serious outcomes. To address this issue, study used newly developed bioabsorbable polyglycolic acid (PGA) sheet to assess its usefulness and safety using two approaches double stapling technique (DST) laparoscopic anterior resection (AR) in pig models.
Despite worldwide clinical use of bio-absorbable devices for internal fixation in orthopaedic surgery, the degradation behaviour and tissue replacement of these implants are not fully understood. In a long-term experimental study, we have determined the patterns of tissue restoration 36 and 54 months after implantation of polyglycolic acid and poly-laevo-lactic acid screws in the distal femur o...
Abbreviations MEMS Microelectromechanical systems NEMS Nano-electromechanical systems PCL Polycaprolactone PET Polyethylene terephthalate PGA Polyglycolic acid PLA Polylactic acid PU Polyurethane PTFE Poly(tetrafl uoroethylene) PMMA Polymethylmethacrylate UHMWPE Ultrahigh molecular weight polyethylene
BACKGROUND The use of biodegradable synthetic nerve conduits for the reconstruction of segmental nerve defects has been extensively reported in both animal and human studies, with a majority of studies evaluating sensory nerve recovery. However, few studies have compared these nerve conduits for functional motor recovery. The purpose of this study was to compare three commercially available, sy...
Cosmetically satisfactory scars were achieved in 94.5% of skin crease orchidopexy wounds sutured with subcuticular polyglycolic acid. Of twenty-seven similar wounds closed with interrupted black silk sutures 18.5% developed hypertrophy at the medial end.
BACKGROUND This study was conducted to determine the efficacy of staple line coverage using a polyglycolic acid patch and fibrin glue without pleural abrasion to prevent recurrent postoperative pneumothorax. METHODS A retrospective analysis was carried out of 116 operations performed between January 2011 and April 2013. During this period, staple lines were covered with a polyglycolic acid pa...