نتایج جستجو برای: potentiometry ion selective membrane electrode

تعداد نتایج: 802881  

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2001
mojtaba shamsipur nahid tavakkoli elham eslami hashem sharghi

two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (l1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (l2) were used as suitable ionophores for the preparation of potassium-selective pvc-membrane electrodes. the resulting electrodes based on l1 and l2 exhibit linear responses to the activity of k+ ions within the concentration ranges of 3.1´10-5 -2.7´10-2 m and 2...

Journal: :journal of physical & theoretical chemistry 2005
m. aghaie m. giahi h. aghaie m. pournaghdy

the preparation of polymer membrane selective to iron(ii) ion and its application to ion-selectiveelectrode is reported here. pvc membrane contains iron–selective n-phenylaza-15-crown-5 asionophore. the membrane electrode is highly selective to iron(ii) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 m with nernstian slope of29.2 ± 0.6 mv per deca...

H. Aghaie M. Aghaie M. Giahi M. Pournaghdy

The preparation of polymer membrane selective to Iron(II) ion and its application to ion-selectiveelectrode is reported here. PVC membrane contains Iron–selective N-phenylaza-15-crown-5 asionophore. The membrane electrode is highly selective to Iron(II) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 M with Nernstian slope of29.2 ± 0.6 mV per deca...

Journal: :journal of physical & theoretical chemistry 2008
n. farahani h. aghaie

fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (pvc) matrixmembrane containing neutral carrier tetra phenyl porphyrin (tpp) ionophore. the addition ofsodium tetraphenylborate (natpb) and the plasticizer dbp has been found to substantiallyimprove the performance of the sensor. the best performance was obtained with the sensor havinga membrane of composition of tpp...

Journal: :Analytica Chimica Acta 2021

The modulation of the ion-fluxes across a polymeric membrane is important for designing attractive methodologies. As an alternative to commonly used dynamic electrochemistry approaches, light can be as external stimulus and provides very convenient way manipulate ions release and/or extraction into membrane. Herein, we designed solid-contact ion-selective sensor that exhibits response by irradi...

Journal: :journal of physical & theoretical chemistry 2011
m.h. fekri m. darvishpour e. baghdar

a poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a cr(iii) selective electrode. the electrode exhibits a good potentiometric response for cr(iii)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 m with a slope 19.5+0.5 mv/decade and low detectionlimit of 8.9 x 10-7 m. it has a fast response time < 15 s. the best perfo...

Journal: :journal of physical & theoretical chemistry 2015
h. aghaie m. h. felcri m. arvand k. zare m. aghaie

a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه علوم پایه دامغان - دانشکده شیمی 1387

چکیده ندارد.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید