نتایج جستجو برای: tower

تعداد نتایج: 9976  

and G. A. Iravani, H. Ahmadikia,

Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...

2004
Dr. Ron Cox

The Cooling Tower Energy & Operating Cost Analysis Software is an in-house program developed by Tower Tech and is used to design and evaluate the performance and life-cycle costs associated with a cooling tower. This version can be used to estimate the cost to purchase and operate a Tower Tech cooling tower and a competitor’s tower. A number of assumptions about the details of the competitor’s ...

Journal: :journal of computational applied mechanics 0
mohammad ali ardekani associate professor, iranian research organization for science and technology (irost), tehran, iran foad farhani assistant professor, iranian research organization for science and technology (irost), tehran, iran mohsen mazidi instructor, iranian research organization for science and technology (irost), tehran, iran

in a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. this is achieved in a cooling tower. the heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout iran. wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. previous studi...

ژورنال: مهندسی دریا 2017

Launching pads are among the essential elements of missiles and their main function is to prepare missiles for launch. Tower launchers dimension and configuration depend on effective loads, dimension and weight of the missile. In the majority of tower launchers, two bars connected to each other with crossbar connectors are considered to be the basic parts. Therefore, it is essential to calculat...

2008
Alp Bassa Arnaldo Garcia Henning Stichtenoth

We present a new explicit tower of function fields (Fn)n≥0 over the finite field with ` = q3 elements, where the limit of the ratios (number of rational places of Fn)/(genus of Fn) is bigger or equal to 2(q2 − 1)/(q + 2). This tower contains as a subtower the tower which was introduced by Bezerra– Garcia–Stichtenoth (see [3]), and in the particular case q = 2 it coincides with the tower of van ...

Amir Rahimi Arezou Nikseir

Beginning with a discussion of energy and exergy analysis definitions, the presented study provides a descriptive mathematical model for energy and exergy analysis for a co-current gas cooling tower. For this purpose using conservation laws of mass, energy and momentum, the variation of temperature and enthalpy of gas and liquid streams are predicted along the tower length and are used in order...

Journal: :Journal of environmental monitoring : JEM 2009
Laurie A Brixey David K Heist Jennifer Richmond-Bryant George E Bowker Steven G Perry Russell W Wiener

This article is the second in a two-paper series presenting results from wind tunnel and computational fluid dynamics (CFD) simulations of flow and dispersion in an idealized model urban neighborhood. Pollutant dispersion results are presented and discussed for a model neighborhood that was characterized by regular city blocks of three-story row houses with a single 12-story tower located at th...

2013
Maik Friedrich Christoph Möhlenbrink

This paper describes the validation of a Remote Tower Control workplace. The study shows how Air Traffic Control Officers (ATCOs) observe traffic from a Tower Control Working Position at Airport Erfurt-Weimar (ERF) in comparison to a Remote Controller Working Position. The validation exercise targets low traffic density airports. Shadow-mode trials were used to cover perceptual, operational and...

Journal: :نشریه دانشکده فنی 0
آرزو نیک سیر امیر رحیمی

beginning with a discussion of energy and exergy analysis definitions, the presented study provides a descriptive mathematical model for energy and exergy analysis for a co-current gas cooling tower. for this purpose using conservation laws of mass, energy and momentum, the variation of temperature and enthalpy of gas and liquid streams are predicted along the tower length and are used in order...

2003
Martin Dimitrov Kassabov Efim Zelmanov

On the Automorphism Tower of Free Nilpotent Groups Martin Dimitrov Kassabov 2003 In this thesis I study the automorphism tower of free nilpo-tent groups. Our main tool in studying the automorphism tower is to embed every group as a lattice in some Lie group. Using known rigidity results the automorphism group of the discrete group can be embedded into the automorphism group of the Lie group. Th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید