نتایج جستجو برای: tower

تعداد نتایج: 9976  

Journal: :international journal of advanced design and manufacturing technology 0
navid bozorgan nariman bozorgan

a thermodynamic analysis of the counter flow wet cooling tower (cwct) in the steelmaking unit of the khuzestan steel company (ksc) is performed in this paper. we evaluated both energy and exergy formulations for analyzing the heat and mass transfer, exergy and second-law efficiency in this cooling tower. the lewis factor le f is an indication of the relative rates of heat and mass transfer in a...

Journal: :international journal of advanced design and manufacturing technology 0
hamidreza goshayeshi amirreza mamouri

cooling towers are widely used in most industrial units to reject waste heat to the atmosphere. this paper deals with an experimental analysis of heat and mass transfer phenomena between water and air by direct contact in a cooling tower. the tower is filled with 6 type packing. in this study temperature and pressure drop and tower characteristics was used in determining experimentally the ther...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2010
mohammad hassan panjeshahi abtin ataei mona gharaie

the present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. the design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables. mor...

Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...

In a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. This is achieved in a cooling tower. The Heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout Iran. Wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. Previous studi...

and G. A. Iravani, H. Ahmadikia,

Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...

Abtin Ataei, Mohammad Hassan Panjeshahi Mona Gharaie

The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....

Journal: :journal of mechanical research and application 2010
navid bozorgan

since the energy analysis considers the quantity of energy, it cannot show the performance of the cooling tower. therefore, in order to optimize the performance of the tower and also the process which the cooling tower is a part of it, it is necessary to analyze the energy and exergy of the tower simultaneously. in this paper, the energy and exergy of one of the cooling towers of khuzestan stee...

Journal: :مطالعات باستان شناسی 0
رضا نظری ارشد دانشجوی دکتری باستان شناسی، گرایش دوران اسلامی، دانشگاه آزاد اسلامی، واحد علوم و تحقیقات تهران محمود طاووسی استاد گروه باستان شناسی، دانشگاه تربیت مدرس سوسن بیانی استادیار گروه باستان شناسی، دانشگاه تهران جواد نیستانی دانشیار گروه باستان شناسی، دانشگاه تربیت مدرس

ghorban tower as an architectural monument is one of the outstanding resting- place of islamic era in hamadan city which has not been studied properly. previous studies on the tower concerning its architectural features or its historical background showed that the tower may be a place where a dignified religious man named khajeh hafez abol'ala hamadani berried inside in saljuk era and afte...

Journal: :international journal of environmental research 2009
a. ataei m.h. panjeshahi m. gharaie n. tahouni

temperature restrictions on aqueous effluents dictate that streams with a temperature higher than the permitted level needed to pass through cooling systems to reduce the effluent temperature before discharge. in this study, by considering the grouping design rules based on pinch technology, an optimum design for a distributed effluent cooling system, has been developed. a counter-flow wet cool...