نتایج جستجو برای: working electrode

تعداد نتایج: 265826  

H. Aghaie M. Giahi M. Zawari

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
Masayuki Itagaki Yasuhiro Fujimura Isao Shitanda Kunihiro Watanabe Toshinori Hachiya

The channel flow double electrode (CFDE) was used for the evaluation of the oxygen reduction activities in alkaline solution of rare-earth oxide-supported silver catalysts. The CFDE cell was modified for the experiment using the powder catalyst as a working electrode. In the present experiment, the silver electrode was supported with CeO2 in order to improve the performance of the oxygen reduct...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده شیمی 1390

abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...

H. Khanmohammadi H. Shafie M. Darvishpour M. H. Fekri R. Aminameli

A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....

A. Farahbakhsh O. Ramezani Azghandi,

The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...

A. Farahbakhsh O. Ramezani Azghandi,

The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...

Journal: :journal of the iranian chemical research 0
zholt kormosh volyn national university, lutsk, ukraine iryna hunka volyn national university, lutsk, ukraine yaroslav bazel p.j. safaric university, slovakia

a simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. a new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine b into graphite matrix. the electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol l-1, a detection limit of 3.9×1...

Journal: :international journal of nano dimension 0
o. ramezani azghandi young researchers club, quchan branch, islamic azad university, quchan, iran. a. farahbakhsh department of chemical engineering, quchan branch, islamic azad university, quchan, islamic republic of iran.

the glucose oxidase (gox) electrochemical sensors were used to detect a little amount of glucose. in this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the ag/agcl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (w.e), reference electrode and auxiliary electrode sequential. factors measured, glucose concentration and ph is phosphate...

This article is a report on a novel and high-stability biosensor with minor interference effects of surface modification of working electrode with β-Ga2O3 nanowires (NWs) on choline oxidase biosensor were investigated in an electrochemical detection system. β-Ga2O3 NWs were materialized on the silicon substrate in a catalyst-free growth mechanism. The β-Ga2O<sub...

2015
Gen Nakagawa Atsushi Kouzuma Atsumi Hirose Takuya Kasai Gen Yoshida Kazuya Watanabe Patrick C. Cirino

In bioelectrochemical systems, the electrode potential is an important parameter affecting the electron flow between electrodes and microbes and microbial metabolic activities. Here, we investigated the metabolic characteristics of a glucose-utilizing strain of engineered Shewanella oneidensis under electrode-respiring conditions in electrochemical reactors for gaining insight into how metaboli...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید