نتایج جستجو برای: working electrode

تعداد نتایج: 265826  

بهجت, عباس, جعفری ندوشن, فاطمه, خوشرو, علیرضا, قشنی, مارال,

Dye-sensitized solar cell (DSSC) using natural Pomegranate juice as dye-sensitizeris fabricated and characterized. DSSCS consist of a working electrode, a redox electrolyte containing iodide and tri-iodide ions and a counter electrode. A nanocrystalline TiO2 semiconductor with a wide band-gap coated with a monolayer dye-sensitizer is used as working electrode. The effect of titanium dioxide (Ti...

Journal: :international journal of nano dimension 0
omid ramezani azghandi department of mechanical engineering, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university) mohammad javad maghrebi department of mechanical engineering, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university) ali reza teymourtash department of mechanical engineering, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university)

in this paper, multi-wall carbon nanotubes (mwcnts), gold nanoparticles (gnp) and glucose oxidase (god) was developed for the specific detection of glucose. mwcnts were chemically modified with the h2so4–hno3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (paa) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/n-hy...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

In this paper, multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hy...

Journal: :iranian chemical communication 2015
reza samimi shalamzari simin mansouri akram eghbali

the conditional formal potential, e°′of methyldopa has been studied by cyclic voltammetry at the surface of activated glassy carbon electrode (agce) as the working electrode in different ph phosphate buffered solutions. the experimental standard redox potential, e°′, of methyldopa is obtained to be 0.72 mv versus she (standard hydrogen electrode). e°′ values have also been calculated with the a...

In this paper, multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hy...

Journal: :journal of physical & theoretical chemistry 2009
m. zawari m. giahi h. aghaie

in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (

1999
Je-Kyun Park Hee-Jin Yee Kang Shin Lee Won-Yong Lee Min-Chol Shin Tae-Han Kim Seung-Ryeol Kim

A differential-type amperometric biosensor based on conventional thick-®lm technology has been developed for breath alcohol measurement. The amperometric breath alcohol biosensor utilizes the alcohol dehydrogenase (ADH) and nicotinamide adenine dinucleotide (NAD‡) cofactor which produce reduced NADH as a product of the oxidation of alcohol. The biosensor was designed in a differential format co...

Journal: :Zeitschrift fur Naturforschung. C, Journal of biosciences 2002
Nina Dimcheva Elena Horozova Zinaida Jordanova

Glucose oxidase (E. C. 1.1.3.4) was immobilized on electrochemically modified graphite to obtain an enzyme electrode. The working surface of the electrode was coated with gelatine to prevent desorption of the enzyme. In substrate (glucose) solutions the amperometric signal of the enzyme electrode was due to the electroreduction of H202 generated in the enzyme layer. The linearity of the electro...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید