نتایج جستجو برای: dose distribution verification

تعداد نتایج: 975918  

2014
Subramani Vikraman Durai Manigandan Karukkupalayam Palaniappan Karrthick Raju Sambasivaselli Vellaingiri Senniandavar Mahendran Ramu Thiyagarajan Rajesh Muller Lutz Manavalan Muthukumaran Nithyanantham Karthikeyan Kataria Tejinder

The purpose of this study was to evaluate quantitatively the patient-specific 3D dosimetry tool COMPASS with 2D array MatriXX detector for stereotactic volumetric-modulated arc delivery. Twenty-five patients CT images and RT structures from different sites (brain, head & neck, thorax, abdomen, and spine) were taken from CyberKnife Multiplan planning system for this study. All these patients...

2014
Teiji Nishio Hiroki Shirato Masayori Ishikawa Yuki Miyabe Satoshi Kito Yuichirou Narita Rikiya Onimaru Satoshi Ishikura Yoshinori Ito Masahiro Hiraoka

A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institut...

Journal: :International journal of radiation oncology, biology, physics 2010
Michael F Gensheimer Torunn I Yock Norbert J Liebsch Gregory C Sharp Harald Paganetti Neel Madan P Ellen Grant Thomas Bortfeld

PURPOSE In proton therapy, uncertainty in the location of the distal dose edge can lead to cautious treatment plans that reduce the dosimetric advantage of protons. After radiation exposure, vertebral bone marrow undergoes fatty replacement that is visible on magnetic resonance imaging (MRI). This presents an exciting opportunity to observe radiation dose distribution in vivo. We used quantitat...

2013
Masao Tanooka Hiroshi Doi Hideharu Miura Hiroyuki Inoue Yasue Niwa Yasuhiro Takada Masayuki Fujiwara Toshiyuki Sakai Kiyoshi Sakamoto Norihiko Kamikonya Shozo Hirota

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

Introduction: Irradiation of loaded tumor with high-Z nanoparticles with low energy photon of 192Ir source during brachytherapy increases absorbed dose of tumor due to increase in possibility of photoelectric phenomena. Therefore, this study aimed to investigate dose enhancement due to nanoparticles (NPs) with different atomic numbers and concentrations as well as effect of NPs distribution (un...

Elham Hossein nezhad Ghazale Geraily, Mahbod Esfahani Mostafa Farzin

Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...

C. Yavas, G. Yavas, H. Acar,

Background: In radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. In this study, the two available calculation algorithms of the Varian Eclipse 8.6 treatment planning system(TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC) was used to compare measured and calculated peripheral dose distributi...

2013
Beong Ik Hur Jae Min Lee Won Ho Cho Dong Wan Kang Choong Rak Kim Byung Kwan Choi

OBJECTIVE The Leksell Gamma Knife® (LGK) is based on a single-fraction high dose treatment strategy. Therefore, independent verification of the Leksell GammaPlan® (LGP) is important for ensuring patient safety and minimizing the risk of treatment errors. Although several verification techniques have been previously developed and reported, no method has ever been tested statistically on multiple...

2015
Iori Sumida Hajime Yamaguchi Hisao Kizaki Keiko Aboshi Mari Tsujii Yuji Yamada Masashi Yagi Kazuhiko Ogawa

Pretreatment dose verification with beam-by-beam analysis for intensity-modulated radiation therapy (IMRT) is commonly performed with a gantry angle of 0° using a 2D diode detector array. Any changes in multileaf collimator (MLC) position between the actual treatment gantry angle and 0° may result in deviations from the planned dose. We evaluated the effects of MLC positioning errors between th...

2010
Daniel A. Low

Quantitative comparisons of dose distributions are an integral component of a medical physicist’s responsibility of assuring high quality radiation therapy dose delivery. While overlays and other displays of multiple dose distributions are useful for such evaluations, quantitative evaluations require a mathematical comparison. The dose-difference is the most straightforward method for comparing...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید