نتایج جستجو برای: spect

تعداد نتایج: 10967  

Objective(s): In view of somatostatin receptor (SSR) expression on cell membranes of the majority of neuroendocrine tumors (NETs), functional imaging exploiting analogs of SSR alongside the anatomical imaging is the mainstay of this diagnostic modality. In this prospective study, we assessed and directly compared the diagnostic parameters of 68Ga-DOTATATE PET/CT and 99...

2017
Shinro Matsuo Kenichi Nakajima Masahisa Onoguchi Hiroshi Wakabayash Koichi Okuda Seigo Kinuya

Objective: A novel multifocal collimator, IQ-SPECT (Siemens) consists of cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 (Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging...

Journal: :Circulation 2013
Raymond J Gibbons Todd D Miller

I n this issue of Circulation, Doukky et al 1 report findings from a cohort of 1511 patients from 11 outpatient community based practices (20 primary care physicians and 2 cardiologists) in the Chicago metropolitan area. The patients underwent single-photon emission computed tomographic (SPECT) myocardial perfusion imaging and were then followed up for 27±10 months for major adverse cardiac eve...

Journal: :Nuclear medicine communications 2012
Babak Shafiei Samaneh Hoseinzadeh Fereidoun Fotouhi Hadi Malek Fereidoun Azizi Adel Jahed Farzad Hadaegh Mohammadtaghi Salehian Hossein Parsa Hamid Javadi Majid Assadi

BACKGROUND Investigations using a hybrid single photon emission computed tomography/computed tomography (SPECT-CT) scanning technique have been carried out in limited studies and have shown mixed results. However, the assessment of this technique for the detection of parathyroid adenoma in patients with a nodular goiter was performed in only one study with a small sample size. The aim of this p...

2016
Geneviève Hassink Enrique Testa André Leumann Thomas Hügle Helmut Rasch Michael T. Hirschmann

BACKGROUND Single Photon Emission Computed Tomography-Computed Tomography (SPECT/CT) gains an important part of diagnostics in patients with osteochondral lesions (OCL). SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and computerized tomography (CT) into one single procedure and combines metabolic data, structural and mechanical information. The purpose of the s...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2006
Nick Dudley Charnie Kalirai

UNLABELLED Precise and reliable assessment of left ventricular (LV) function and dimensions is prognostically important in cardiac patients. As the integration of SPECT and multislice CT into hybrid scanners will promote the combined use of both techniques in the same patient, a comparison of the 2 methods is pertinent. We aimed at comparing LV dimensions, muscle mass, and function obtained by ...

Journal: :Neurology 2014
Vlastimil Sulc Samantha Stykel Dennis P Hanson Benjamin H Brinkmann David T Jones David R Holmes Richard A Robb Matthew L Senjem Brian P Mullan Robert E Watson Daniel Horinek Gregory D Cascino Lily C Wong-Kisiel Jeffrey W Britton Elson L So Gregory A Worrell

OBJECTIVE To evaluate the benefit of statistical SPECT processing over traditional subtraction methods, we compared ictal-interictal SPECT analyzed by statistical parametric mapping (SPM) (ISAS), statistical ictal SPECT coregistered to MRI (STATISCOM), and subtraction ictal-interictal SPECT coregistered with MRI (SISCOM) in patients with MRI-negative focal temporal lobe epilepsy (nTLE) and extr...

Journal: :Annals of nuclear medicine 2002
Yasuyuki Takahashi Kenya Murase Hiroshi Higashino Teruhito Mochizuki Nobutoku Motomura

PURPOSE Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. METHODS Registerion (fusion) of the X-ray CT and SPECT ima...

2016
Haishan Zhang Shi Gao Bin Chen Guanghui Cheng

The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)3-(Arg-Gly-Asp)2 (99mTc-3P4-RGD2) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prospectively investigated a consecutive series of 24 patients with SPN, who were newly diagnosed using radiog...

2013
Kengo Ito Etsuro Mori Hidenao Fukuyama Kazunari Ishii Yukihiko Washimi Takashi Asada Satoru Mori Kenichi Meguro Shin Kitamura Haruo Hanyu Seigo Nakano Hiroshi Matsuda Yasuo Kuwabara Kazuo Hashikawa Toshimitsu Momose Yoshitaka Uchida Jun Hatazawa Satoshi Minoshima Kenji Kosaka Tatsuo Yamada Yoshiharu Yonekura

OBJECTIVE The multicenter prospective cohort study (Japan Cooperative SPECT Study on Assessment of Mild Impairment of Cognitive Function: J-COSMIC) aimed to examine the value of (123)I-N-isopropyl-4-iodoamphetamine cerebral blood flow (IMP-CBF) SPECT in regards to early diagnosis of Alzheimer's disease (AD) in patients with mild cognitive impairment (MCI). METHODS Three hundred and nineteen p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید