Background and purpose: The chemical quality of feed water to dialysis instrument is very important, especially in terms of heavy metals which could cause serious health problems for dialysis patients. This study aimed to determine the concentration of selected heavy metals (lead, cadmium, chromium and zinc) in feed water to dialysis instrument and compared that with EPH and AAMI standards in h...
background: the presence of heavy metals in dialysis water which enters patients’ body through haemodialysis can cause various problems such as acute poisoning, brain damage, osteoarthritis etc. therefore, applying the standards for dialysis water is indispensable. this study was carried out to determine the heavy metals of the enterence water of dialysis machines and its comparison with aami a...
Previous studies have suggested that older adults with age-associated memory impairment (AAMI) may show a significant decline in attentional resource capacity and inhibitory processes in addition to memory impairment. In the present paper, the potential attentional capture by task-irrelevant stimuli was examined in older adults with AAMI compared to healthy older adults using scalp-recorded eve...
The 14-unit T-maze has proven to be a valuable tool for investigating age-associated memory impairment (AAMI). While another task widely used to evaluate AAMI, the water maze, is primarily used to evaluate allocentric hippocampal-dependent spatial memory, the 14-unit T-maze can assess egocentric procedural memory. Although several brain structures, e.g. hippocampus, parietal cortex, have been i...
background the chemical and physical quality of water used for dialysis fluid is a vital factor in the patients overall care who receive dialysis. therefore, the water used for this purpose must be treated with advanced methods before being used for dialysis. conclusions the evaluation of hemodialysis water quality showed that these hospitals were not significantly polluted and the water qualit...
A study was undertaken to assess the accuracy of the Omron HEM-907 blood pressure measuring device for use in community studies. A modified version of the British Hypertension Society (BHS) and American Association for the Advancement Medical Instrumentation (AAMI) protocol for measuring the accuracy of a blood pressure measuring device was used. A total of 104 subjects were recruited from two ...
This study aims to validate blood pressure (BP) values measured by an oscillometric BP monitor and seek possible calibration methods if discrepancies exist. Noninvasive BP measurement outcomes were determined using an oscillometric BP monitor (Omron HBP-1300) versus a mercury sphygmomanometer (standard device). Two percent of subjects enrolled in an epidemiological investigation were systematic...