نتایج جستجو برای: gc fid
تعداد نتایج: 36940 فیلتر نتایج به سال:
A method based on silica gel chromatography and GC-MS/GC-FID analyses was developed for the quantitation of alkaloidal compounds in imported fire ants, Solenopsis richteri, S. invicta, and their hybrid found in the southern United States. The cis and trans alkaloids from fire ant body extracts were successfully separated by silica gel chromatography, identified by GCMS, and quantitated by GC-FI...
Previously, we reported that tasar silkworm pupal oil (TPO) is a rich source of alpha-linolenic acid (ALA) (37%). In this study, have used three chromatographic techniques, namely preparative HPLC, gas chromatography-mass spectroscopy (GC-MS), and chromatography flame ionization detection (GC-FID), to purify, determine, quantify (ALA), respectively, from TPO. Additionally, determine the potenti...
In this study, two methods are developed for the extraction of 1,4-dioxane (dioxane) from water using 80-microm carboxen-polydimethylsiloxane solid-phase microextraction fibers followed by either gas chromatography (GC)-flame ionization detection (FID) or GC-mass spectrometry (MS). With GC-FID, the lower limit of detection (LOD) for 1,4-dioxane is 2.5 microg/L (ppb) with a linear range of 5 to ...
روش میکرواستخراج فاز جامد به عنوان یک روش تجاری برای آماده سازی نمونه ها توسط بلاردی و پائولزین در سال 1989 ارائه شد. استفاده از نانولوله های کربنی برای تهیه پوشش در روش میکرواستخراج فاز جامد و با توجه به رفتار مکانیکی، الکتریکی و شیمیائی آن ناتوانیهای فیبرهای تجاری را به میزان زیادی برطرف کرده است. روشهای متفاوتی برای تهیه پوشش نانولوله های کربنی جهت استفاده در میکرواستخراج فاز جامد وجود دارد ...
Quantifying non-methane hydrocarbons (NMHC) from animal feeding operations (AFOs) is challenging due to the broad spectrum of compounds and the polar nature of the most abundant compounds. The purpose of this study was to determine the performance of commercial NMHC analyzers for measuring volatile organic compounds (VOCs) commonly emitted from AFOs. Three different NMHC analyzers were tested f...
GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...
GC-FID and HPLC-DAD were developed for determination of menadione (MN) and menadione sodium bisulphite (MSB). By means of each method, quantitative analysis of MSB in commercial pharmaceutical was performed in both direct analysis of MSB and analysis of MN by converting MSB to MN with sodium carbonate. GC-FID method was carried out on the HP-5 capillary column using nitrogen gas. HPLC-DAD metho...
The determination of residual solvents in pharmaceuticals is one of the most important gas chromatography (GC) applications in quality assurance/quality control (QA/QC) in the pharmaceutical industry. Sample introduction is normally done using static headspace (SHS). In routine QC, GC with flame ionization detection (FID) is preferred, while mass spectrometry (MS) can be used for screening and ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید