نتایج جستجو برای: hip prosthesis

تعداد نتایج: 88373  

2017
Mohsen Farzi Richard M. Morris Jeannette Penny Lang Yang Jose M. Pozo Søren Overgaard Alejandro F. Frangi Jeremy Mark Wilkinson

Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not readily resolved using conventional DXA analysis. DXA region free analysis (DXA RFA) is a novel comp...

2015
M Moga ME Pogarasteanu A Barbilian

Hip arthrosis, primary or secondary, is an osteoarthritic degenerative process that affects the hip joint. Primary hip arthrosis has an unknown etiology, and secondary hip arthrosis has well defined causes; of these causes, some are known to lead to arthrosis of the hip in the young age patient. The surgical treatment aims either to preserve the patient’s hip joint, or to replace the joint. The...

2013
Qing-jiang Pang Xiao Yu Xian-jun Chen Zhen-chun Yin Guo-zhong He

OBJECTIVE To explore the treatment strategies and clinical effect of the acetabular malunion with traumatic arthritis by total hip arthroplasty. METHODOLOGY A retrospective analysis was conducted on 47 cases of acetabular malunion with traumatic arthritis from June 2000 to December 2009. All the patients underwent total hip arthroplasty with bone grafting or titanium cage for bone defect of t...

2009
AC Unger H Cabrera-Palacios AP Schulz Ch Jürgens A Paech

INTRODUCTION At present there are no reliable non-traumatic and non- invasive methods to analyse the healing process and loosening status after total hip replacement. Therefore early as well as late loosening of prosthesis and interface component problems are difficult to be found or diagnosed at any time. METHODS In a cadaver study the potential application of Resonance Frequency Monitoring ...

Journal: :Collegium antropologicum 2001
I D Bajs V Sarić M Opalić

Following total hip arthroplasty the durability of a prosthetic implant depends on many factors but is generally limited by two types of damage: wearing of frictional surfaces of the acetabular and femoral component as well as the loosening and migration of the "rosthesis-cement-bone" system. Since it is possible to establish a cause-and-effect relationship between these two damage types, the a...

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

2014
Jong Hoon Kim Sung Kwang Chun Yong Cheol Yoon Devendra Lakhotia Won Yong Shon

PURPOSE In early prosthetic joint infection after hip arthroplasty, debridement with prosthesis retention may be performed for implant salvage, but the reported success rates are highly variable. Hence we reviewed the outcome of radical debridement and retention of prosthesis using established diagnostic criteria and surgical procedures in relation to significant variables including clinical ch...

2015

Objective: to characterize the epidemiological profile of patients undergoing hip replacement, primary or revisional. Methods: we conducted a retrospective, descriptive study, including hip arthroplasties performed from January 2009 to June 2012 in a Belo Horizonte teaching hospital, Minas Gerais State – MG, Brazil. Data were analyzed using descriptive statistics. Results: orthopedic procedures...

2016
Nora Renz Fabienne Chevaux Olivier Borens Andrej Trampuz

BACKGROUND Granulicatella and Abiotrophia spp. are difficult to detect due to their complex nutritional requirements. Infections with these organisms are associated with high treatment failure rates. We report the first implant-associated infection caused by Granulicatella para-adiacens, which was cured with anti-microbial treatment consisting of anti-biofilm-active rifampin and debridement, ex...

Journal: :Acta orthopaedica Belgica 2011
Bhavuk Garg Ravi Mittal Shishir Rastogi

Fracture of the femoral prosthesis neck following total hip arthroplasty is not common. We report a case of femoral prosthesis neck fracture in an adult male patient following modular, uncemented total hip arthroplasty. This case report further emphasizes the importance of the potentially high loading situation in the prosthetic femoral neck. On the other hand, the occurrence of a femoral prost...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید