نتایج جستجو برای: hysteresis loop relaxation time

تعداد نتایج: 2057350  

2003
W. Wernsdorfer

The one-body tunnel picture of single-molecule magnets (SMMs) is not always sufficient to explain the measured tunnel transitions. An improvement to the picture is proposed by including also two-body tunnel transitions such as spin-spin cross-relaxation (SSCR) which are mediated by dipolar and weak superexchange interactions between molecules. A Mn4 SMM is used as a model system. At certain ext...

2000
Sug-Bong Choe Sung-Chul Shin

We report experimental evidence that submicron-scale local coercivity variation determines magnetization reversal dynamics in ferromagnetic thin films. Local coercivity distribution is generated from a twodimensional array of hysteresis loops each of 0.3230.32 mm spots simultaneously measured using a magneto-optical microscope magnetometer. We directly demonstrate that domain reversal pattern i...

Journal: :Optics express 2016
Yun-Han Lee Fangwang Gou Fenglin Peng Shin-Tson Wu

We demonstrate a polymer network liquid crystal (PNLC) with negligible hysteresis while keeping submillisecond response time. By doping about 1% dodecyl acrylate (C12A) into the liquid crystal/monomer precursor, both hysteresis and residual birefringence are almost completely eliminated. The operating voltage and scattering properties remain nearly intact, but the tradeoff is enhanced double re...

2002
Jonathan P. Rothstein Gareth H. McKinley

Filament stretching experiments are used to follow the evolution in the flow-induced birefringence (FIB) and the tensile force in polymeric fluid threads undergoing uniaxial elongation. The tests are performed with several monodisperse polystyrene solutions spanning concentrations from 0.025 to 12 wt.%, and the measurements are used to investigate the extent of hysteresis in the polymeric stres...

Two nondestructive electromagnetic/magnetic techniques including hysteresis loop and eddy current methodologies have been used to characterize microstructural changes of AISI D2 cold work tool steel as a result of quench and tempering treatments. To measure the fraction retained austenite in quenched microstructure, six specimens were austenitized in the range  of 1000-1130 °C. Samples austenit...

Journal: :Materials Research 2014

This paper considers the problem of adaptive output feedback tracking control for a class of nonstrict-feedback nonlinear systems with unknown time-varying delays and unknown backlash-like hysteresis. Fuzzy logic systems are used to estimate the unknown nonlinear functions. Based on the Lyapunov–Krasovskii method, the control scheme is constructed by using the backstepping and adaptive techniqu...

2017
Nikhil Kumar Clemens Winkelmann Sourav Biswas Hervé Courtois Anjan K. Gupta C. B. Winkelmann

We demonstrate control of the thermal hysteresis in superconducting constrictions by adding a resistive shunt. In order to prevent thermal relaxation oscillations, the shunt resistor is placed in close vicinity of the constriction, making the inductive current-switching time smaller than the thermal equilibration time. We investigate the current-voltage characteristics of the same constriction ...

In this paper, for the first time to our knowledge, we investigate the optical bi-stability in a compact parallel array of micro- ring resonators with 5μm radius, induced by optical nonlinearity. Due to the nature of perfect light confinement, resonance and accumulation process in a ring resonator, optical nonlinear effects, even at small optical power of a few milliwatts in this structure are ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید