In this study, highly ordered mesoporous silica material (SBA-15) functionalized with Diethyl 2 - (9 -fluorenyl) malonate as a flourophore is reported. The anchoring of flourophores to the hydroxyl group on SBA-15 surface was done with post synthesis method. The obtained materials were characterized by small and wide angle X-ray diffraction, N2 adsorption–desorption, Fourier transform infrared ...
In this research, a Dispersive Liquid-Liquid MicroExtraction (DLLME) method coupled to UV-vis spectrophotometry was developed for the indirect determination of silver ion. The method is based on the catalytic effect of the silver ion on the oxidation of congo red by potassium peroxodisulphate and extraction with DLLME procedure using chloroform (extraction solvent) containing cetyltrimethyl...
A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...
A simple, sensitive and accurate method for spectrophotometric determination of Dalacinphosphatehas been established. The method is based on the reduction of atomic absorptioncalcium ion by phosphate. Because, there is a phosphate mole in every Dalacin mole structureand with measurement of phosphate, Dalacin is beyond measurement too. Therefore, the reactionbetween acidic hydrolysis products of...
چکیده با کاهش ابعاد ترانزیستورهای ماسفت و نزدیک شدن به حد نانومتری، شیب زیر آستانه ترانزیستورها زیاد می¬شود. بالا بودن شیب زیر آستانه در این ترانزیستورها و داشتن نسبت ion/ioff پایین، کاربرد آنها را در مدارهای دیجیتال و آنالوگ دچار چالش می¬کند. برای کاهش شیب زیر آستانه و همچنین افزایش نسبت ion/ioff، ساختارهای تازه ای معرفی شده است که ترانزیستورهای اثر میدانی تونل زنی یکی از آنها است. این تران...
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
A simple analytical system suitable for nephelometric measurements is introduced in this article. The electronic and optical components are simplified so that the apparatus is easily assembled from materials that are generally available. This instrument is designed for the efficient measurement of anions, and microgram quantities of ions may be determined by a convenient method of titration...
a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...
a pvc ion-selective membrane electrode based on cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of mno4- ion. this electrode revealed good selectivity toward permanganate ion over a widevariety of anions. effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
a simple, sensitive and accurate method for spectrophotometric determination of dalacinphosphatehas been established. the method is based on the reduction of atomic absorptioncalcium ion by phosphate. because, there is a phosphate mole in every dalacin mole structureand with measurement of phosphate, dalacin is beyond measurement too. therefore, the reactionbetween acidic hydrolysis products of...
نمودار تعداد نتایج جستجو در هر سال