Journal: :Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia 2007
Nada Jiraskova Pavel Rozsival Jana Kadlecova Jana Nekolova Jana Pozlerova Zlatica Dubravska

AIMS To compare the metrics and surgical outcome when using Infiniti AquaLase and NeoSoniX cataract removal modalities. METHODS This prospective clinical study involved 50 patients with bilateral cataracts and lens removal using AquaLase in the right eye and NeoSoniX in the left eye. Best corrected visual acuity (BCVA), endothelial cell density and pachymetry were evaluted pre- and postoperat...

2015
Mohammad Mehdi Sadoughi Bahram Einollahi Neda Einollahi Javad Rezaei Danial Roshandel Sepehr Feizi

PURPOSE To compare ultrasound pachymetry and Orbscan II for measurement of central corneal thickness (CCT) in normal eyes. METHODS The current study was performed at Labbafinejad Medical Center (LMC), Tehran, Iran. Three hundred eyes from 150 healthy individuals referred for keratorefractive surgery were assessed first by Orbscan II and then by ultrasound pachymetry, and CCT values were recor...

Journal: :Journal of cataract and refractive surgery 2003
Jose Manuel González-Méijome Alejandro Cerviño Eva Yebra-Pimentel Manuel A Parafita

PURPOSE To compare thickness measurements of the central 6.0 mm of the cornea obtained with the Orbscan(R) II topography system and topographical ultrasound pachymetry. SETTING School of Optometry, University of Santiago de Compostela, Galicia, Spain. METHODS In 24 right eyes, pachymetric measurements were taken at the center and 1.2 mm and 3.0 mm on the superior and inferior hemimeridians....

Journal: :Contact lens & anterior eye : the journal of the British Contact Lens Association 2015
Nienke Soeters Esther Simone Visser Saskia M Imhof Nayyirih G Tahzib

OBJECTIVES To investigate the influence of full scleral lenses on corneal curvature and pachymetry in keratoconus patients. METHODS In this intervention study, 20 eyes of 14 patients were measured by Scheimpflug imaging (Pentacam HR, Oculus) at two time points: directly and ≥1 week after scleral lens removal. Steep, flat and maximal keratometry (K(steep), K(flat) and K(max)) and optical pachy...

Journal: :Cornea 2007
Erica Brugin Alessandra Ghirlando Catia Gambato Edoardo Midena

PURPOSE To compare the repeatability and validity of corneal pachymetry by a corneal confocal microscope with a z-axis adapter (Confoscan 4.0 with z-ring adapter: z-CS4) versus ultrasound (US) pachymetry in the measurement of central corneal thickness (CCT). METHODS CCT in 44 eyes of 44 subjects was determined with z-CS4. Z-CS4 exams were used to estimate the repeatability of thickness measur...

Journal: :Ophthalmology 2004
Joshua W Kim Philip P Chen

PURPOSE To investigate the association between corneal pachymetry and visual field progression in patients with chronic open-angle glaucoma. DESIGN Retrospective case-control study. PARTICIPANTS Eighty-eight patients with primary open-angle glaucoma, pseudoexfoliative glaucoma, pigmentary glaucoma, or normal-tension glaucoma, followed for an average of 8 years, who had visual field loss and...

Journal: :Investigative ophthalmology & visual science 2010
Jens Bühren Daniel Kook Geunyoung Yoon Thomas Kohnen

PURPOSE. To assess the suitability of corneal anterior and posterior surface aberrations and thickness profile data for discrimination between eyes with early keratoconus (KC), fellow eyes of eyes with early KC, and normal eyes. METHODS. Thirty-two eyes (group 1) of 25 patients were newly diagnosed with KC; 17 eyes of 17 patients (group 2) were asymptomatic fellow eyes without clinical signs of...

Journal: :بینا 0
محمدرضا جعفری نسب mr jafarinasab ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم سپهر فیضی s feizi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم فرید کریمیان f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم شهرام صالحی راد sh salehirad ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم حسین حسن پور h hasanpour ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranتهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات چشم

purpose: to assess the agreement of ultrasonic pachymetry, the galilei dual scheimpflug analyzer and orbscan ii in measuring central corneal thickness (cct) in normal and keratoconic eyes. methods: in this prospective comparative study, cct was measured in 88 refractive surgery candidates and 76 (39 right) eyes of 45 keratoconic patients using ultrasonic pachymetry, galilei and orbscanii. readi...

2015
Jinhai Huang Giacomo Savini Chengfang Wang Weicong Lu Rongrong Gao Yuanguang Li Qinmei Wang Yune Zhao

Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by 1 operator using the TMS-5, 3 additional consecutive scans were performed by a second operator, a...

2016
Mehrdad Mohammadpour Kazem Mohammad Nasser Karimi

PURPOSE To evaluate the agreement among Pentacam, Orbscan and ultrasound (US) pachymetry for measurement of central corneal thickness (CCT) in thin corneas with normal topographic pattern. METHODS We included 88 eyes of 44 refractive surgery candidates with thinnest pachymetric readings of 500 micrometers (μm) or less on Orbscan, a normal topographic pattern, no sign of keratoconus, and best ...