AIMS To compare the metrics and surgical outcome when using Infiniti AquaLase and NeoSoniX cataract removal modalities. METHODS This prospective clinical study involved 50 patients with bilateral cataracts and lens removal using AquaLase in the right eye and NeoSoniX in the left eye. Best corrected visual acuity (BCVA), endothelial cell density and pachymetry were evaluted pre- and postoperat...
PURPOSE To compare ultrasound pachymetry and Orbscan II for measurement of central corneal thickness (CCT) in normal eyes. METHODS The current study was performed at Labbafinejad Medical Center (LMC), Tehran, Iran. Three hundred eyes from 150 healthy individuals referred for keratorefractive surgery were assessed first by Orbscan II and then by ultrasound pachymetry, and CCT values were recor...
PURPOSE To compare thickness measurements of the central 6.0 mm of the cornea obtained with the Orbscan(R) II topography system and topographical ultrasound pachymetry. SETTING School of Optometry, University of Santiago de Compostela, Galicia, Spain. METHODS In 24 right eyes, pachymetric measurements were taken at the center and 1.2 mm and 3.0 mm on the superior and inferior hemimeridians....
OBJECTIVES To investigate the influence of full scleral lenses on corneal curvature and pachymetry in keratoconus patients. METHODS In this intervention study, 20 eyes of 14 patients were measured by Scheimpflug imaging (Pentacam HR, Oculus) at two time points: directly and ≥1 week after scleral lens removal. Steep, flat and maximal keratometry (K(steep), K(flat) and K(max)) and optical pachy...
PURPOSE To compare the repeatability and validity of corneal pachymetry by a corneal confocal microscope with a z-axis adapter (Confoscan 4.0 with z-ring adapter: z-CS4) versus ultrasound (US) pachymetry in the measurement of central corneal thickness (CCT). METHODS CCT in 44 eyes of 44 subjects was determined with z-CS4. Z-CS4 exams were used to estimate the repeatability of thickness measur...
PURPOSE To investigate the association between corneal pachymetry and visual field progression in patients with chronic open-angle glaucoma. DESIGN Retrospective case-control study. PARTICIPANTS Eighty-eight patients with primary open-angle glaucoma, pseudoexfoliative glaucoma, pigmentary glaucoma, or normal-tension glaucoma, followed for an average of 8 years, who had visual field loss and...
PURPOSE. To assess the suitability of corneal anterior and posterior surface aberrations and thickness profile data for discrimination between eyes with early keratoconus (KC), fellow eyes of eyes with early KC, and normal eyes. METHODS. Thirty-two eyes (group 1) of 25 patients were newly diagnosed with KC; 17 eyes of 17 patients (group 2) were asymptomatic fellow eyes without clinical signs of...
purpose: to assess the agreement of ultrasonic pachymetry, the galilei dual scheimpflug analyzer and orbscan ii in measuring central corneal thickness (cct) in normal and keratoconic eyes. methods: in this prospective comparative study, cct was measured in 88 refractive surgery candidates and 76 (39 right) eyes of 45 keratoconic patients using ultrasonic pachymetry, galilei and orbscanii. readi...
Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by 1 operator using the TMS-5, 3 additional consecutive scans were performed by a second operator, a...
PURPOSE To evaluate the agreement among Pentacam, Orbscan and ultrasound (US) pachymetry for measurement of central corneal thickness (CCT) in thin corneas with normal topographic pattern. METHODS We included 88 eyes of 44 refractive surgery candidates with thinnest pachymetric readings of 500 micrometers (μm) or less on Orbscan, a normal topographic pattern, no sign of keratoconus, and best ...