نتایج جستجو برای: pachymetry

تعداد نتایج: 1158  

Journal: :Bulletin de la Societe belge d'ophtalmologie 2001
G Sallet

In 100 eyes of 50 patients central corneal thickness was measured comparing optical to ultrasound pachymetry. With optical pachymetry the values were 1 to 40 micrometer (microns) lower in 64 eyes compared to ultrasound pachymetry. With ultrasound pachymetry the values were 1 to 18 microns lower in 26 eyes compared to optical pachymetry. In 10 cases no difference in pachymetry readings was seen ...

2017
In Kyun Hahn Jae Yong Kim Myoung Joon Kim Hungwon Tchah Chan Hee Moon

PURPOSE To assess the validity of central corneal thickness (CCT) and corrected intraocular pressure (IOP) values obtained by tono-pachymetry in non-surgical and post-photorefractive keratectomy (PRK) eyes. METHODS For the study, 108 young healthy participants and 108 patients who had PRK were enrolled. Measurements were randomly performed by tono-pachymetry, ultrasonic (US) pachymetry, and G...

2008
Amir Faramarzi Hossein Ziai

PURPOSE To compare Orbscan II and ultrasonic pachymetry for measurement of central corneal thickness (CCT) in eyes scheduled for keratorefractive surgery. METHODS CCT was measured using Orbscan II (Bausch & Lomb, USA) and then by ultrasonic pachymetry (Tomey SP-3000, Tomey Ltd, Japan) in 100 eyes of 100 patients with no history of ocular surgery scheduled for excimer laser refractive surgery....

Journal: :Ophthalmology 2006
Shiro Amano Norihiko Honda Yuki Amano Satoru Yamagami Takashi Miyai Tomokazu Samejima Miyuki Ogata Kazunori Miyata

PURPOSE To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. DESIGN Experimental study. PARTICIPANTS Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. METHODS Corneal thickness measurements were compared among the 3 me...

Journal: :The British journal of ophthalmology 2004
K Kawana T Tokunaga K Miyata F Okamoto T Kiuchi T Oshika

AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...

2004
K Kawana

Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...

2015
Wassia A Khaja Sandeep Grover Amy T Kelmenson Lee R Ferguson Kumar Sambhav Kakarla V Chalam

BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many stud...

2014
José M González-Méijome Daniela Lopes-Ferreira Laura Rico-del-Viejo Patrícia Neves Helena Ferreira José Salgado-Borges

Purpose: To evaluate the agreement of pachymetry data provided by a new instrument to measure intraocular pressure (IOP) and the corneal biomechanical response with the values provided by Pentacam in healthy and keratoconic eyes. Methods: Fifty-four right eyes from 54 healthy patients (32 females, 22 males) and 82 eyes from 43 keratoconus patients (20 females, 23 males) were included in the stu...

2015
David Finis Bernhard Ralla Maria Karbe Maria Borrelli Stefan Schrader Gerd Geerling

Aim. The aim of this study was to determine the intra- and interobserver variability of two Scheimpflug based camera systems, Pentacam and Sirius. In addition, the comparability of the measurements was tested in healthy subjects, subjects with regular astigmatism, and keratoconus patients. Methods. Intra- and interobserver variability were assessed in 20 healthy corneas. Pachymetry values were ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید