نتایج جستجو برای: reactive power and load current harmonic

تعداد نتایج: 17000499  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی خواجه نصیرالدین طوسی - دانشکده مهندسی برق و کامپیوتر 1391

many mobile and off-grid devices include electronics and other electrical consumers like servo drives, which need a quite low supply power. since the price for photovoltaic modules drops continuously, photovoltaic power supply is interesting in more and more applications. in solar powered systems, a battery is needed to store energy for the night and cloudy periods. the power electronics of suc...

2014
P. Shah

This paper describes a novel fuzzy logic controller for a three phase shunt active shunt filter for the power quality improvement. The Power Quality (PQ) problems in power distribution systems are not new but only recently the effects of these problems have gained public awareness. These non-linear loads are constructed by nonlinear devices in which the current is not proportional to the applie...

Voltage and reactive power control have been widely employed to reduce power losses and satisfy the main distribution system operational constraints. In recent years, Distributed Generators connected to the distribution network have received increasing attention. The connection of enormous DGs into existing distribution network changes the operation of distribution systems and affect the daily ...

2012
Rajesh Kr. Ahuja Aasha Chauhan Sachin Sharma

Recently wide spread of power electronic equipment has caused an increase of the harmonic disturbances in the power systems. The nonlinear loads draw harmonic and reactive power components of current from ac mains. Current harmonics generated by nonlinear loads such as adjustable speed drives, static power supplies and UPS. Thus a perfect compensator is required to avoid the consequences due to...

2015
J. N. Pandya

This paper represents the simulation of Shunt Active Power Filter(SAPF) based on p-q theory and using hysteresis current control to obtain the gating signals for three phase ac-dc converter. The proposed active power filter is employed to reduce the current Total Harmonic Distortion (THD) drawn by the non-linear load and compensate the reactive power. The PI controller is employed to reduce the...

2013
Chen Wenjie

In order to detect grid harmonic and reactive current precisely and real time, this paper arrived at a method of harmonic and reactive current real-time detection applied to active power filter based on the three-phase circuit instantaneous reactive power theory. With Matlab simulation software, researches on simulation of harmonic detection means are carried out, and an analysis of the simulat...

2015
S. Alwin Dr. M. Marsaline Beno

This paper deals with an indirect current controlled shunt active power filter (SAPF) for improving power quality by reactive power compensation and harmonic filtering. The presence of harmonics and reactive power in the power source because it will cause additional power losses and malfunctions. The proposed APF is based on a voltage source inverter (VSI). The VSI is controlled by two loops, t...

2014
K. Prasada Rao

This paper proposes the improved methodology of power quality in grid interconnected photo voltaic system by using shunt active power filter . With development of new functionalities solar energy based Photovoltaic cells are upcoming energy source with higher efficiency. Solar energy being naturally available in abundance and nonpolluting is one of the most promising sources. Excessive use of p...

2014
Y.Anil Kumar

Harmonic pollution of the power supply system has risen significantly in recent years due primarily to an increase of non-linear loads connected to the utility through residential, commercial and industrial customers. Power supply voltages become distorted due to the high level of undesired harmonic current drawn from the utility. Additionally, drops in fundamental voltage are caused by the int...

The paper presents a super-twisting sliding mode (STSM) regulator with neural networks (NN) of direct power command (DPC) for controlling the active/reactive power of a doubly-fed induction generator (DFIG) using a two-level space vector pulse width modulation (2L-SVPWM). Traditional DPC strategy with proportional-integral (PI) controllers (DPC-PI) has significantly more active/reactive power r...

نمودار تعداد نتایج جستجو در هر سال