نتایج جستجو برای: siemens primus linac

تعداد نتایج: 9554  

2011
Klaus Bratengeier Mark B Gainey Michael Flentje

PURPOSE The purpose of this work is to develop fast deliverable step and shoot IMRT technique. A reduction in the number of segments should theoretically be possible, whilst simultaneously maintaining plan quality, provided that the reduction is accompanied by an increased number of gantry angles. A benefit of this method is that the segment shaping could be performed during gantry motion, ther...

C Knaup, F Akbari F Khorshidi, M Ghorbani, M T Bahreyni Toosi N Mohammadian

Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3...

Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
J P Lin T C Chu S Y Lin M T Liu

This study involves the measurement of photoneutron contamination emitted from a Siemens Primus medical linear accelerator by using BD-PND bubble detectors. Various bubble detectors were arranged around the linac head with the interval of I m and at the same height as the isocenter to measure the dose equivalent distribution in the treatment room. The measurements were performed for 15 MV X-ray...

2016
M.T. Bahreyni Toossi F. Khorshidi M. Ghorbani N. Mohamadian D. Davenport

BACKGROUND EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. OBJECTIVE The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. METHODS Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose wa...

2009
DO Odero DS Shimm

Radiation therapy requires precision to avoid unintended irradiation of normal organs. Electronic Portal Imaging Devices (EPIDs), can help with precise patient positioning for accurate treatment. EPIDs are now bundled with new linear accelerators, or they can be purchased from the Linac manufacturer for retrofit. Retrofitting a third party EPID to a linear accelerator can pose challenges. The a...

2017
Mikaeil Molazadeh Ahad Zeinali Mostafa Robatjazi Alireza Shirazi Ghazale Geraily

This study evaluated the basic dosimetric characteristics of a Dynamic Multi Leaf Collimator (DMLC) using a diode detector and film measurements for Intensity Modulated Radiation Therapy Quality Assurance (IMRT QA). The EGSnrc Monte Carlo (MC) simulation system was used for the determination of MLC characteristics. Radiation transmission and abutting leaf leakage relevant to the LinaTech DMLC H...

2016
M.T. Bahreyni Toosi N. Mohamadian M. Ghorbani F. Khorshidi F. Akbari C. Knaup

OBJECTIVE Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer. METHODS A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT...

Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید