نتایج جستجو برای: ct number linearity
تعداد نتایج: 1306030 فیلتر نتایج به سال:
The American College of Radiology (ACR) Computed Tomography (CT) Accreditation Program requires submission of phantom scans acquired with the ACR accreditation phantom. There is a known issue with some wide-beam scanners in which the Hounsfield unit (HU) value of water may be correct when using the scanner manufacturer's phantom, but will be out of range in some scan modes when scanning the acc...
clinical trial committee (ctc) has been established in food and drug organization (fdo), in 2003 to assure efficacy and safety of all types of medicinal products which are meant to be registered in iran drug list and/or obtain market authorization.all clinical trial files, meeting minutes and databases in ctc secretariat in fdo were reviewed. relevant information and data extracted, analyzed an...
growing demands and requires of high data rate systems cause significant increase of high frequency systems for wideband communication applications. as mixers are one of the main blocks of each receivers and its performance has great impact on receiver’s performance; in this thesis, a new solution for ku-band (12-18 ghz) mixer design in tsmc 0.18 µm is presented. this mixer has high linearity a...
A continuous-time (CT) sigma-delta modulator (SDM) for condenser microphone readout interfaces is presented in this paper. The CT SDM can accommodate a single-ended input and has high input impedance, so that it can be directly driven by a single-ended condenser microphone. A current-sensing boosted OTA-C integrator with capacitive feedforward compensation is employed in the CT SDM to achieve h...
A single spinal motoneuron receives tens of thousands of synapses. The neurotransmitters riving potential of the linear sum ct of this non-linearity on the current delivered to the soma during activation of predetermined numbers and distributions of excitatory and inhibitory synapses. To accomplish this goal we constructed compartmental models constrained by detailed measurements of the geometr...
A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...
in the present study application of x-ray computed tomography as a nondestructive technique for estimation of some qualitative parameters of pomegranate fruit was studied. for this purpose, three local cultivars of pomegranate fruit of fars province, iran that included; rabab malas, rabab torsh and khani kazeroon were used. the x-ray ct images of pomegranate fruits were prepared using ct-scan d...
introduction: computed tomography (ct) and cone-beam ct (cbct) are valuable diagnostic aids for many clinical applications. this study was designed to compare the gray scale value (gsv) and hounsfield unit (hu) of selected dental materials and various hard tissues using ct or cbct. methods and materials: three samples of all test materials including amalgam (am), composite resin (cr), glass ion...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید