نتایج جستجو برای: transformer winding

تعداد نتایج: 16464  

Journal: :CoRR 2016
Bjorn Gustavsen Alvaro Portillo Rodrigo Ronchi Asgeir Mjelve

—Transformer terminal equivalents obtained via admittance measurements are suitable for simulating high-frequency transient interaction between the transformer and the network. This paper augments the terminal equivalent approach with a measurement-based voltage transfer function model which permits calculation of voltages at internal points in the regulating winding. The approach is demonstrat...

In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...

2004
M. SADEGHIAN MARDANEH M. HOSSEINI G. B. Gharehpetian

In this paper, a new method for estimation of transient parameters of transformer high voltage winding using the artificial neural networks (ANN) is proposed. An ANN with different structures is trained for parameters estimation of transformer winding Detailed Model that data is generated by analysis of frequency response. It is shown that feed-forward back propagation network with Levenberg-Ma...

2001
Liang Yan Brad Lehman

A new integrated magnetic full wave dc/dc converter1 that provides flexible transformer design by incorporating an independent output inductor winding is introduced. The transformer is implemented on a traditional three-leg magnetic core. The inductor winding can be separately designed to control the output current ripple. The cross-sectional area of the inductor core leg can be reduced dramati...

2014
M.Arivamudhan S.Santhi

Leakage reactance is one of the most important specifications in transformer that has significant impact on its overall design. Variation in leakage reactance serves as a diagnostic measure to indicate mechanical integrity of power transformers before and after a short circuit test that demonstrates mechanical strength of transformer windings. This paper presents an approach for leakage reactan...

Journal: :نشریه دانشکده فنی 0
حسین محسنی فرامرز رهبر

usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...

2006
A. Shintemirov Q. H. Wu

This paper presents an improved model of uniform transformer winding for frequency response analysis (FRA), based on traveling wave theory. The accurate representation of the losses and detailed consideration of measurement chains are the main features of the model. The transfer function expression of the transformer winding and equivalent distributed-parameter circuit for FRA have been derived...

2012
M. Srinivasan A. Krishnan

The Hot Spot Temperature (HST) value depends on the ambient temperature, the rise in the top oil temperature (TOT) over the ambient temperature, and the rise in the winding HST over the top oil temperature. In this paper a new semi-physical model comprising of the environmental variables for the estimation of HST and loss of insulation life in transformer is proposed. The winding hot-spot tempe...

2017
Zhongyong Zhao Chao Tang Qu Zhou Lingna Xu Yingang Gui Chenguo Yao

A transformer is the most valuable and expensive property for power utility, thus ensuring its reliable operation is a major task for both operators and researchers. Online impulse frequency response analysis has proven to be a promising technique for detecting transformer internal winding mechanical deformation faults when a power transformer is in service. However, as so far, there is still n...

2013
Mohd Zaifulrizal ZAINOL Nasrudin ABD. RAHIM Jeyraj SELVARAJ

A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer. This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Finally, the experimental set up is built to transfer power of 300 W over the different gap var...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید