نتایج جستجو برای: 6mv photons

تعداد نتایج: 47464  

Journal: :Medical physics 2013
A Faught S Davidson S Kry J Fontenot C Etzel G Ibbott D Followill

PURPOSE To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. PURPOSE To commission a multiple-source Monte Carlo model of Elekta linear accelerator beams of nominal energies 6MV and 10MV. METHODS A three source, Monte Carlo model of Elekta 6 and 10MV therapeutic x-ray...

Journal: :Australasian Physics & Engineering Sciences in Medicine 2003

2015
Tatsiana A. Reynolds Patrick Higgins

The purpose of this study was to review application of a consistent correction method for the solid state detectors, such as thermoluminescent dosimeters (chips (cTLD) and powder (pTLD)), optically stimulated detectors (both closed (OSL) and open (eOSL)), and radiochromic (EBT2) and radiographic (EDR2) films. In addition, to compare measured surface dose using an extrapolation ionization chambe...

Journal: :Medical physics 2012
T Karan V Moiseenko B Gill R Horwood A Minchinton

PURPOSE To establish a radiobiological basis for gated stereotactic body radiotherapy of primary and metastatic liver cancers using volumetric arc radiotherapy in a flattening filter free (FFF) mode. METHODS Human cervical carcinoma, SiHa, non-small cell lung carcinoma, H460, and Chinese hamster V79 cells were irradiated in a water bath with 6MV photons from a Varian TrueBeam linear accelerat...

2014
Daniel G. Zhang Vladimir Feygelman Eduardo G. Moros Kujtim Latifi Geoffrey G. Zhang Mohammed Yousfi

MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitati...

The semi-classical model of atom-field interaction has been fully studied for some multilevel atoms, e.g. Vee, L, Cascade X , Y, and inverted Y and so on. This issue is developed into the full-quantum electrodynamics formalism, where the probe and coupling electromagnetic fields are quantized. In this article, we investigate the full-quantum model of absorption and dispersion spectrum of trappe...

2016
Ananda Giri Babu Alagar Ganesh Kadirampatti Mani Kaviarasu Karunakaran

Small fields smaller than 4 × 4 cm2 are used in stereotactic and conformal treatments where heterogeneity is normally present. Since dose calculation accuracy in both small fields and heterogeneity often involves more discrepancy, algorithms used by treatment planning systems (TPS) should be evaluated for achieving better treatment results. This report aims at evaluating accuracy of four model-...

2014
Maria F. Chan David Lewis Xiang Yu

PURPOSE To assess the possibility of using a public calibration function for radiochromic film dosimetry in dose QA of highly conformal treatment plans. METHODS EBT3 film calibration strips (3.5 × 20 cm2 from lots A101212 and A011713) were exposed on a Varian Trilogy at a facility to a 10 × 10 cm2 open field at doses of 80, 160, 320 cGy using 6MV photons. Together with a strip of unexposed fi...

2013
Louise Murray Ann Henry Peter Hoskin Frank-Andre Siebert Jack Venselaar

A review of planning studies was undertaken to evaluate estimated risks of radiation induced second primary cancers (RISPC) associated with different prostate radiotherapy techniques for localised prostate cancer. A total of 83 publications were identified which employed a variety of methods to estimate RISPC risk. Of these, the 16 planning studies which specifically addressed absolute or relat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید