نتایج جستجو برای: 6mv photons

تعداد نتایج: 47464  

Journal: :iranian journal of radiation research 0
z. falahatpour department of medical radiation engineering, shahid beheshti university, tehran, iran s.m.r. aghamiri department of medical radiation engineering, shahid beheshti university, tehran, iran r. anbiaee department of radiotherapy and oncology, imam hossein hospital, tehran, iran

background: tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. this method is performed by using 2d and 3d treatment planning. the aim of this study was to compare 2d with 3d plans in breast conserving radiotherapy. homogeneity of isodose, and lung received dose were compared. materials and methods: twenty patients with breast canc...

Farideh Farokhi Moghadam

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

2005

ID: 3490 Title: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy Purpose: To investigate the computed non-tumor integral dose (NTID) delivered during treatment of prostate cancer with intensity modulated radiotherapy (IMRT) compared to three-dimensional conformal radiotherapy (3DCRT). Low and highenergy photon treatments were also evaluated in this study, as was helical tom...

2006

ID: 4805 Title: For small field Radiosurgery Intermediate Energy Photons (800kV) show superior dose distributions compared to megavoltage beams Purpose: Beam penumbra is significant when using stereotactic radiosurgery to treat small volumes with limited microscopic extensions. It is challenging to irradiate these lesions if a highly critical structure is in close contact with the target. Previ...

Journal: :International journal of radiation oncology, biology, physics 2006
Hidefumi Aoyama David Clark Westerly Thomas Rockwell Mackie Gustavo H Olivera Søren M Bentzen Rakesh R Patel Hazim Jaradat Wolfgang A Tome Mark A Ritter Minesh P Mehta

BACKGROUND This study was designed to evaluate the integral dose (ID) received by normal tissue from intensity-modulated radiotherapy (IMRT) for prostate cancer. METHODS AND MATERIALS Twenty-five radiation treatment plans including IMRT using a conventional linac with both 6 MV (6MV-IMRT) and 20 MV (20MV-IMRT), as well as three-dimensional conformal radiotherapy (3DCRT) using 6 MV (6MV-3DCRT)...

2017
Suresh Tamilarasu Madeswaran Saminathan S K Sharma Anjali P Abhinav Dewan

Aim: To evaluate the plan quality of 6MV unflattened (UFB) and flattened beam (FB) photon energy using AAA dose calculation algorithms for volumetric arc therapy. Materials and Methods: Plans were generated for bilateral carcinoma of breast and the dose prescribed was 50.4Gy in 28 fractions. Two different plans were made for each patient using 6MV FB and 6MV UFB. Dose calculations were performe...

Farideh Farokhi Moghadam

Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment tech...

Journal: :Medical physics 2012
L Bartol L DeWerd

PURPOSE Effective treatment planning for radiotherapy is dependent on accurate spectra determination; however, direct measurements of spectra arecomplicated by fluence rates that exceed detection system limitations. This work demonstrates the potential to use a Compton scattering technique to measure the spectrum of a 6MV linac. These spectra are further characterized using Monte Carlo (MC) sim...

2012
Laure Bobyk Magali Edouard Pierre Deman Julia Rousseau Jean-François Adam Jean-Luc Ravanat François Estève Jacques Balosso Rolf F Barth Hélène Elleaume

BACKGROUND The purpose of the present study was to compare side-by-side the therapeutic efficacy of a 6-day infusion of carboplatin, followed by X-irradiation with either 6 MV photons or synchrotron X-rays, tuned above the K-edge of Pt, for treatment of F98 glioma bearing rats. METHODS Carboplatin was administered intracerebrally (i.c.) to F98 glioma bearing rats over 6 days using AlzetTM osm...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید