نتایج جستجو برای: ehv power transmission

تعداد نتایج: 709126  

2016
Sushil Kumar

ENHANCEMENT OF POWER SYSTEM STABILITY BY SIMULTANEOUS AC-DC POWER TRANSMISSION Dr. Sushil Kumar Principal Pragati college of Engg. & Management,Raipur [email protected] Abstract It is difficult to load extra high voltage (EHV) ac lines to their thermal limits as a sufficient margin is kept against transient instability.This paper proposed a model in which it will be possible to load these ...

Journal: :Energy Reports 2021

Extra-high voltage (EHV) lines of 500–750 kV, providing transmission electricity over long distances and at the same time performing functions intersystem communication level national power system, play an important role not only in normal modes, but also emergency ensuring dynamic stability system as a whole. In these lines, overwhelming proportion cuts are caused by single-phase short circuit...

2016
Haileleul Negussie Yewei Li Tesfaye Sisay Tessema Hans J. Nauwynck

Replication kinetics and invasion characteristics of equine herpesvirus-1 and -3 (EHV-1/-3) in nasal and vaginal mucosae were compared using explants. The explants were cultured during 96 h with little change in viability. The tissues were inoculated with EHV-1 03P37 (neuropathogenic), 97P70 (abortigenic) and EHV-3 04P57, collected at 0, 24, 48 and 72 h post inoculation (pi) and stained for vir...

2009
E. A. Mohamed H. A. Talaat E. A. Khamis

This paper presents a design for a fault diagnosis system (FDS) for tapped high/extra-high voltage (HV/EHV) power transmission lines (TL's). These tapped lines have two different protection zones. The proposed approach reduces the cost and the complexity of the FDS for these types of lines. The FDS, basically, utilizes fifteen artificial neural networks (ANN's) to reach its output diagnosis. Th...

Journal: :iranian journal of veterinary research 2015
yakup yildirim volkan yilmaz ali kirmizigul

the herpesviruses infections in equides are caused by five different serotypes of viruses, belonging to family herpesviridae. the goal of this study was to conduct a seroepidemiological investigation of equine herpesvirus type 1 (ehv-1) and type 4 (ehv-4) in horses and donkeys raised in two provinces and their villages in northeastern turkey. a total of 666 samples from 423 horses and 243 donke...

Journal: :Journal of virology 2012
Hideto Fukushi Tsuyoshi Yamaguchi Souichi Yamada

Equine herpesvirus type 9 (EHV-9), which we isolated from a case of epizootic encephalitis in a herd of Thomson's gazelles (Gazella thomsoni) in 1993, has been known to cause fatal encephalitis in Thomson's gazelle, giraffe, and polar bear in natural infections. Our previous report indicated that EHV-9 was similar to the equine pathogen equine herpesvirus type 1 (EHV-1), which mainly causes abo...

Journal: :Equine veterinary journal 2015
M L Schulman A Becker B D van der Merwe A J Guthrie T A E Stout

REASONS FOR PERFORMING STUDY Equine herpesvirus 1 (EHV-1) is one of the most common causes of infectious abortion in mares. Analysing the demography of outbreaks and detailing subsequent reproductive performance of affected mares will assist in the management of future (threatened) epizootics. OBJECTIVES To examine the epidemiology and reproductive outcomes of 2 EHV-1 abortion epizootics with...

Journal: :The Journal of veterinary medical science 2008
Kerstin Borchers Dietmar Lieckfeldt Arne Ludwig Hideto Fukushi George Allen Robert Fyumagwa Richard Hoare

Equid herpesvirus 9 (EHV-9) was isolated from a herd of Thomson's gazelles affected by encephalitis. The natural host of EHV-9 is unknown, but zebras are suspected to be the source of infection in gazelles. To prove this hypothesis, we analyzed 43 sera from Burchell's zebras (Equus burchelli) and 21 Thomson's gazelles (Gazella thomsoni) from the Serengeti ecosystem for neutralizing antibodies. ...

Journal: :Energija 2022

This paper deals with the application of neural networks to fault location on extra-high voltage (EHV) transmission lines. A relatively simple power system, consisting two 220 kV grids connected one line, has been modelled using MATLAB/Simulink software. Simulating different scenarios (fault types, locations, resistances, and inception angles), proposed network locator was trained various sets ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید