نتایج جستجو برای: ehv power transmission
تعداد نتایج: 709126 فیلتر نتایج به سال:
در زندگی امروزی مصرف انرژی الکتریکی به دلیل سهولت انتقال، تولید در میزان گسترده و سهولت تبدیل آن به سایر اشکال انرژی پر رونق تر گردیده است و هم چنین در سالهای اخیر مقدار توانی که بایستی از مکانهای تولید به نواحی اصلی بار انتقال داده شود رشد کاملاً محسوسی را نشان می دهد. به دلیل هزینه های سنگین تجهیزات تولید، انتقال و توزیع و همچنین نیاز به سیستم های برق رسانی مطمین، طرح های بهینه برای قسمتهای مخ...
چکیده ندارد.
Multi-phase (employing phases more than three) power transmission systems have been investigated as a potential alternative to conventional three-phase systems for bulk power transmission at EHV and UHV levels in the past. The technology has been found to be effective to remove some of the limitations of threephase system arising out of the use of extremely high voltages to increase power capab...
چکیده ندارد.
Now-a-days, demand for electric power has shown steady but geographically uneven growth.The wheeling of the available energy through existing long ac lines to load centers has a certain upper limit due to stability considerations. Thermal limit is the major limit to be considered while increasing loadability of existing EHV long transmission lines. Thus, these lines cannot be loaded to their th...
This paper presents the concept of simultaneous ac-dc power transmission. Long extra high voltage (EHV) ac lines cannot be loaded to their thermal limits due to this instability occurs in the power system. It is difficult to load long extra high voltage (EHV) ac lines to their thermal limits as a sufficient margin is kept against transient instability. With the model proposed in this thesis, it...
Transient stability plays key role for the loading of Extra High Voltage AC lines under their thermal limits. It is not possible to load these EHV lines near the thermal limits. But, with the proposed scheme in this paper, it is possible to load these lines very close to their thermal limits. Master current controller senses ac current and regulates the dc current orders for converters online s...
Equine herpesviruses (EHV) infect horses early during life and the persistence of these viruses through establishment of latency represents a real risk. A better understanding of the immune response to EHV infection is necessary to improve our methods of prevention and decrease the risk of transmission. The objectives of this study were to characterise the cytokine gene expression profile of pe...
This paper presents the design and analysis of a compensation method with application to a 345 kV 480 MVA three-phase transmission line. The compensator system includes a series injected voltage source converter that minimizes the resonance effects of capacitor line reactance. This creates an ability to compensate for the effects of subsynchronous resonance and thereby increase line loadability...
The possible relationship between human exposure to electromagnetic environment in the vicinity to high and extra high voltage (EHV) power transmission lines and their adverse health effects has become a subject to considerable public interest and concern. The preparation of this review have been carried out for the purpose of quantitative assessment of biological interaction and to evaluate th...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید