Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
Mark Konijnenberg Marleen Melis Roelf Valkema Eric Krenning Marion de Jong

UNLABELLED Ex vivo autoradiographs of healthy kidney tissue from patients who received (111)In-DTPA-octreotide (DTPA is diethylenetriaminepentaacetic acid) before nephrectomy showed very heterogeneous radioactivity patterns in the kidneys. The consequences of the reported inhomogeneities have been evaluated for radionuclide therapy with (90)Y- DOTA-Tyr(3)-octreotide (DOTA is 1,4,7,10-tetraazacy...

Davood khezerloo Mohammad Ali Behrooz Mohammad Javad T ahmasebi, Mojtaba karbalai Shole Arvandi

Introduction: Nowadays,  considerable developments  in  the field  of  radiotherapy have  been  achieved.  They  include  the  advances  made  in  the  equipments  and  treatment  planning  techniques  which  require  highly complex calculations. Such achievements have made it possible to treat cancer patients not only  with  higher  radiation  dose  but  also  with  higher  precision  and  con...

Alireza Nikoofar Khadijeh Asnaashari Mahbobeh Nazarnejad, Mahdi Sadeghi Seied Rabi Mahdavi

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

Azizollah Rahimi Bijan Hashemi, Mohammad Hassan Zahmatkesh Ramin Jaberi Shahab Sheibani

Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR) Ir-192 wi...

الهی, مهدی, مهدوی, سید ربیع, هاشمی, بیژن,

Background and purpose: The human body is composed of various inhomogenous tissues with a variety of physical and radiological properties. These inhomogeneities could change isodose distributions, increase the probability of geometric errors, and eventually lead to missing of the target irradiation or incorrect isodose coverage in conformal radiation therapy (CRT) due to the uncertainties resul...

2014
Tamer Dawod E. M. Abdelrazek Mostafa Elnaggar Rehab Omar

Aim: The purpose of this study was to make a comparison between measured and calculated physical wedge dose distributions using the superposition algorithm. Settings and Design: The accurate determination of absorbed dose is important radiotherapy because of the relatively steep sigmoidal dose response curves for both tumor control and normal-tissue damage. Materials and Methods: High-energy ph...

Journal: :The American journal of roentgenology, radium therapy, and nuclear medicine 1973
F Alaníz-Camino D Espejo

I T HAS been recognized that intracavi-tary irradiation is essential in the treatment of carcinoma of the uterine cervix. Since the beginning of the present century3 many applicators have been used to irradiate the uterus and vagina and later several afterloading techniques have been de-scnibed. " 4 Some of the techniques involve the use of remote control5 " and linear distribution of the sourc...

Journal: :iranian journal of medical physics 0
azizollah rahimi msc student of medical physics, tarbiat modares university, tehran, iran. bijan hashemi associate professor, medical physics dept., tarbiat modares university, tehran, iran. mohammad hassan zahmatkesh assistant professor, novin medical radiation institute, tehran, iran. ramin jaberi physicist, cancer institute, department of radiotherapy and oncology, imam khomeini hospital, tehran, iran. shahab sheibani assistant professor, nuclear sciences research center, nuclear science and technology research center, tehran, iran.

introduction: polymer gels are modern dosimeters providing three dimensional dose distributions. these dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. in this study, the ability of the magica polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (ldr) ir-192 wi...

Journal: :iranian journal of medical physics 0
mohammad javad t ahmasebi associated professor, medical physics & radiotherapy dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran mohammad ali behrooz professor, medical physics dept., ahwaz university of medical sciences, ahwaz, iran shole arvandi assistant professor, radiotherapy & oncology dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran davood khezerloo m.sc. medical physics dept., ahwaz university of medical sciences, ahwaz, iran mojtaba karbalai m.sc. medical physics dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran

introduction: nowadays,  considerable developments  in  the field  of  radiotherapy have  been  achieved.  they  include  the  advances  made  in  the  equipments  and  treatment  planning  techniques  which  require  highly complex calculations. such achievements have made it possible to treat cancer patients not only  with  higher  radiation  dose  but  also  with  higher  precision  and  con...

Journal: :iranian journal of nuclear medicine 2008
ali asghar mowlavi mejed yazdani

bebig ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. the plaques consist of a thin film of 106ru, a beta emitter, encapsulated in pure silver. the present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. this new model includes detailed descript...