نتایج جستجو برای: ncat digital phantom gated treatment planning conventionaltreatment planning

تعداد نتایج: 1903689  

Journal: :iranian journal of radiation research 0
m.n. anjum mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 w. parker mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 i. aldahlawi mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 r. ruo mcgill university health centre l5-112, 1650-cedar avenue, montreal general hospital, canada h3g 1a4 m. afzal department of physics, the islamia university of bahawalpur, pakistan

background: we have validated the monitor unit calculations from a commercially available treatment planning system (tps) for three intensity modulated radiotherapy (imrt) planning techniques for tangential breast irradiation by using ionization chamber measurements. materials and methods: treatment plans were generated for forty-two breast patients by a forward planned field in field technique...

2009
Jiali Wang Misael del Valle Juan Franquiz Anthony McGoron

Purpose: To develop and validate an automatic algorithm for the detection and functional assessment of lung tumors on three-dimensional respiratory gated PET/CT images. Method and Materials: First the algorithm will automatically segment lung regions in CT images, then identify and localize focal increases of activity in lung regions of PET images at each gated bin. Once the tumor voxels have b...

آقامیری, محمودرضا , باغانی, حمیدرضا , حسینی دقیق, محسن , مهدوی, ربیع ,

Background and purpose: Dose calculations in trachea HDR brachytherapy treatment planning systems are greatly based on TG-43 protocol in which, all materials including air inside trachea are treated the same as water. The aim of this study was to survey the effect of air on dose calculations of Flexiplan treatment planning system in trachea HDR brachytherapy. Materials and methods: To ev...

2011
Jason E. Matney Brent C. Parker Daniel W. Neck Greg Henkelmann Isaac I. Rosen

This study evaluated the accuracy of measuring the motion of an internal target using four-dimensional computed tomography (4DCT) scanning and the BrainLAB ExacTrac X-ray imaging system. Displacements of a metal coil implanted in a commercial respiratory phantom were measured in each system and compared to the known motion. A commercial respiratory motion phantom containing a metal coil as a su...

2017
M. Ismail M. Afzal M. Nadeem A. M. Rana S. Amjad S. A. Buzdar

*Corresponding author: Muhammad Ismail, Department of Physics, Bahauddin Zakariya University, Multan, 60800-Pakistan. E-mail: [email protected] Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being use...

Journal: :iranian journal of radiation research 0
h. acar selcuk university, faculty of medicine, department of radiation oncology, konya, turkey g. yavas selcuk university, faculty of medicine, department of radiation oncology, konya, turkey c. yavas konya training and research hospital, department of radiation oncology, konya, turkey

background: broca’s and wernicke’s areas, which are important language areas of brain, are commonly irradiated in patients with right frontal lobe glioblastomamultiforme (gbm). we aimed to compare two different treatment planning techniques in terms of the doses in the broca’s and wernicke’s areas for the patients with right frontal gbm. materials and methods: two different treatment planning t...

Elham Boroghani Hamid Reza Baghani Ramezan Eidi Ramin Jaberi Seied Rabi Mahdavi Seyed Mahmoud Aghamiri Seyed Mohsen Hosseini Daghigh,

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

Journal: :iranian journal of medical physics 0
reza faghihi school of mechanical engineering, nuclear engineering department, shiraz university, shiraz, iran radiation research center, shiraz university, shiraz, iran

introduction after the publication of task group number 43 dose calculation formalism by the american association of physicists in medicine (aapm), this method has been known as the most common dose calculation method in brachytherapy treatment planning. in this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

2001
Christopher T. Baird George Starkschall H. Helen Liu Thomas A. Buchholz Kenneth R. Hogstrom

The accuracy of the photon convolution/superposition dose algorithm employed in a commercial radiation treatment planning system was evaluated for conditions simulating tangential breast treatment. A breast phantom was fabricated from machineable wax and placed on the chest wall of an anthropomorphic phantom. Radiographic film was used to measure the dose distribution at the axial midplane of t...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2004
P Rodrigues A Trindade L Peralta C Alves A Chaves M C Lopes

In this paper, we present a novel implementation of a dose calculation application, based on the GEANT4 Monte Carlo toolkit. Validation studies were performed with an homogeneous water phantom and an Alderson-Rando anthropomorphic phantom both irradiated with high-energy photon beams produced by a clinical linear accelerator. As input, this tool requires computer tomography images for automatic...