نتایج جستجو برای: triplex tube heat exchanger

تعداد نتایج: 302472  

Journal: :international journal of advanced design and manufacturing technology 0
mohsen ghazikhani emad noorifar ali mohammadian

in this paper the effect of block shape vortex generators (vgs) on an air-water fin-tube heat exchanger has been studied experimentally using exergy analysis method. also the effect of these vgs on increasing heat transfer rate has been simulated numerically and the results show a good agreement with the experiments. in this research we used a wind tunnel to produce wind flow over heat exchange...

In this paper the thermal behavior of the shell-side flow of a shell-and-tufe heat exchanger has been studied using theoretical and experimental methods. The experimental method Provided the effect of the major parameters of the shell-side flow on thermal energy exchange. In the numerical method, besides the effect of the major paramerers, the effect of different geometric parameters and Re on ...

Journal: :journal of heat and mass transfer research(jhmtr) 2014
seyed faramarz ranjbar mir hatef seyyedvalilu

helical coil heat exchangers are widely used in industrial applications ranging fromcryogenic processes, air-conditioning, and nuclear reactors to waste heat recovery due totheir compact size and high heat transfer coefficient. in this kind of heat exchangers, flowand heat transfer are complicated. this paper reports a numerical investigation of theinfluence of different parameters such as coil...

In the presented research, heat transfer of a mobile electrolyte alkaline fuel cell (AFC) (which the electrolyte has cooling role of system) has been considered. Proper control volumes of system with specific qualification have been chosen. Consequently, heat and mass transfer in control volumes have been assessed. Considerations on them and contributed models lead to approve a double tube heat...

Journal: :international journal of automotive engineering 0
sadighi dizaji jafarmadar

if an air flow is injected into a liquid fluid, many ambulant air bubbles are formed inside the fluid. air bubbles move inside the liquid fluid because of the buoyancy force, and the mobility of these air bubbles makes sizable commixture and turbulence inside the fluid. this mechanism was employed to enhance the heat transfer rate of a horizontal double pipe heat exchanger in this paper. howeve...

2002
R. Donald Morgan

Over 85% of all new heat exchanger applications in oil refining, chemical, petro-chemical, and power generation are accommodated through the use of conventional shell and tube type heat exchangers. The fundamental basis for this statistic is shell and tube technology is a cost effective, proven solution for a wide variety of heat transfer requirements. However, there are limitations associated ...

2013
Frithjof Engel David Meyer Susan Krumdieck

This paper presents how the thermal performance of an existing finned-tube heat exchanger is determined experimentally. In the experiment, heat is transferred from an exhaust gas stream to a thermal oil. The experimental setup is discussed including the thermal fluid selection process, the components, instrumentation and resultant measurement uncertainty. The heat transfer is calculated individ...

1998
Scott D. Dahl Jane H. Davidson

The use of natural convection, side-arm heat exchangers in solar domestic water heating systems is becoming a popular method of reducing system cost and electric demand. In this paper, we compare thermal performances of three natural convection heat exchangers mounted along the outside of the water storage tank and a commercial wraparound-tank heat exchanger to two forced-flow heat exchangers. ...

2014
Long Huang Vikrant Aute Reinhard Radermacher Long HUANG Vikrant AUTE Reinhard RADERMACHER

Microchannel heat exchangers (MCHXs) are now widely used in the HVAC&R industry. Similar to tube-fin heat exchangers used mainly in the indoor units, the innovative variable geometry microchannel heat exchanger will further reduce its compact size and enhance its performance. Variable geometry refers to a heat exchanger with different tube and fin surfaces within the same core with one or more ...

2009
Varun Singh Reinhard Radermacher Jungho Kim

Title of Document: DEVELOPMENT OF AN ADVANCED HEAT EXCHANGER MODEL FOR STEADY STATE AND FROSTING CONDITIONS Varun Singh Doctor of Philosophy, 2009 Directed By: Reinhard Radermacher, Professor Department of Mechanical Engineering Air-to-refrigerant fin-and-tube heat exchangers are a key component in the heating, air conditioning and refrigeration industry. Considering their dominance, the indust...

نمودار تعداد نتایج جستجو در هر سال