نتایج جستجو برای: biosensor

تعداد نتایج: 9306  

2007
Muawia Salameh Alqasaimeh Lee Yook Heng Musa Ahmad

An optical urea biosensor was fabricated by stacking several layers of sol-gelfilms. The stacking of the sol-gel films allowed the immobilization of a Nile Bluechromoionophore (ETH 5294) and urease enzyme separately without the need of anychemical attachment procedure. The absorbance response of the biosensor was monitoredat 550 nm, i.e. the deprotonation of the chromoionophore. This multi-laye...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2005
Dawei Pan Jinhua Chen Shouzhuo Yao Wenyan Tao Lihua Nie

An amperometric glucose biosensor is developed that is based on immobilization of glucose oxidase (GOD) in a composite film of poly(o-aminophenol) (POAP) and carbon nanotubes (CNT), which are electrochemically co-polymerized at a gold (Au) electrode. Because of the high surface per volume ratio and excellent electrical conductivity of CNT, the biosensor based on an Au/POAP/CNT/GOD electrode has...

2013
Murat Kavruk Veli Cengiz Özalp Hüseyin Avni Öktem

A paper-based biosensor was developed for the detection of the degradation products of organophosphorus pesticides. The biosensor quantifies acetylcholine esterase inhibitors in a fast, disposable, cheap, and accurate format. We specifically focused on the use of sugar or protein stabilizer to achieve a biosensor with long shelf-life. The new biosensor detected malathion with a detection limit ...

Journal: :Molecular bioSystems 2014
Ahmed Saied F Belal Brittney R Sell Hiofan Hoi Michael W Davidson Robert E Campbell

Fluorescent protein (FP)-based biosensors have revolutionized the ability of researchers to monitor enzyme activities in live cells. While the basic design principles for FP-based biosensors are well established, first-generation biosensor constructs typically suffer from relatively low fluorescence responses that limit their general applicability. The protein engineering efforts required to su...

2017
Steven J. Setford Jeffrey D. Newman

The biosensor field has grown enormously since the first demonstration of the biosensor concept by Leland C. Clark Jr. in 1962. Today’s biosensor market is dominated by glucose biosensors, mass-produced enzyme-electrodes for the rapid self-diagnosis of blood glucose levels by diabetes sufferers. Here we take a historical look at the inception, growth, and development of the enzyme biosensor fie...

2007
Lingrui Zhang Da Xing Junsheng Wang

In this paper, a new principle biosensor for non-invasive monitoring of the regulation of photosynthetic metabolism based on quantitative measurement of delayed fluorescence (DF) is developed. The biosensor, which uses light-emitting diode lattice as excitation light source and a compact Single Photon Counting Module to collect DF signal, is portable and can evaluate plant photosynthesis capaci...

Journal: :Analytical chemistry 2012
Chung-Liang Wang Lan-Yi Wei Chiun-Jye Yuan Kuo Chu Hwang

This work presents a simple, low-cost and reusable label-free method for detecting protein tyrosine kinase activity using a tyrosinase-based amperometric biosensor (tyrosine kinase biosensor). This method is based on the observation that phosphorylation can block the tyrosinase-catalyzed oxidation of tyrosine or tyrosyl residue in peptides. Therefore, the activity of p60c-src protein tyrosine k...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Juan-C Vidal E Garcia Juan-R Castillo

The preparation of a cholesterol amperometric biosensor using a platinized Pt electrode as a support for the electropolymerization of a polypyrrole film, in which cholesterol oxidase and ferrocene monocarboxylic acid (electron-transfer mediator) were co-entrapped, is described. All the biosensor preparation steps (platinization and electropolymerization) and the cholesterol determination take p...

Journal: :Biosensors & bioelectronics 2011
M F Barroso C Delerue-Matos M B P P Oliveira

In this paper, a biosensor based on a glassy carbon electrode (GCE) was used for the evaluation of the total antioxidant capacity (TAC) of flavours and flavoured waters. This biosensor was constructed by immobilising purine bases, guanine and adenine, on a GCE. Square wave voltammetry (SWV) was selected for the development of this methodology. Damage caused by the reactive oxygen species (ROS),...

Journal: :Nanoscale research letters 2016
T P Velychko О О Soldatkin V G Melnyk S V Marchenko S K Kirdeciler B Akata A P Soldatkin A V El'skaya S V Dzyadevych

Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید