نتایج جستجو برای: dosimetry calculation

تعداد نتایج: 109521  

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :Archivos espanoles de urologia 2006
Pedro J Prada German Juan José Fernández H González-Suárez Alvaro Martínez José González Ana Alonso

OBJECTIVE Low dose rate (LDR) prostate brachytherapy (permanent 125I or 103Pd seeds) is an accepted treatment option for low risk prostate cancer patients. However, differences in prostate spatial location, volume and gland deformation between the images obtained during pre-planning and later on during the implant procedure prevent the pre-planned intended dose to be accurately delivered. We ar...

Journal: :Zeitschrift fur medizinische Physik 2011
Thomas Goetzfried Mark Rickhey Marius Treutwein Oliver Koelbl Ludwig Bogner

Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were r...

2017
Li-Hong Yao Jun-Jie Wang Charles Shang Ping Jiang Lei Lin Hai-Tao Sun Lu Liu Hao Liu Di He Rui-Jie Yang

BACKGROUND A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths - with different number as well as activities of 125I seeds. METHODS The radiation dosimetry of three representative ra...

A. Binesh, A.A. Mowlavi, H. Moslehitabar,

Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...

2006
CHOONSIK LEE JAI-KI LEE

Phantoms for radiation dosimetry, including physical phantoms for radiological use in medicine in particular, were introduced as early as the 1910s [1] while those for radiation protection dosimetry started to evolve in the late 1950s. This innovation was driven partly from the consensus that dose quantity for protection purposes should be assessed in “receptor conditions” instead of the tradit...

Journal: :Cancer biology & therapy 2011
Jeffrey N Bryan Fang Jia Huma Mohsin Geethapriya Sivaguru Carolyn J Anderson William H Miller Carolyn J Henry Michael R Lewis

BACKGROUND We previously described a two-antibody model of (64)Cu radioimmunotherapy to evaluate low-dose, solid-tumor response. This model was designed to test the hypothesis that cellular internalization is critical in causing tumor cell death by mechanisms in addition to radiation damage. The purpose of the present study was to estimate radiation dosimetry for both antibodies (mAbs) using po...

ژورنال: سنجش و ایمنی پرتو 2018

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

2017
Grzegorz Zwierzchowski Grzegorz Bieleda Janusz Skowronek

Background Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and planar film dosimetry is also increasingly used for verification of the dose distribution in BT applications. Using the gamma analysis m...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید