نتایج جستجو برای: electric transformer

تعداد نتایج: 154144  

2013
Mohammadreza Barzegaran M. R. Barzegaran M. Mirzaie

Detecting and removing minor faults in power transformer winding is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. In this paper in order to detect the position of short-circuit in the winding, frequency response of the input impedance of a power transformer is analyzed. Common short-circuits are categorized and the results are compa...

2003
Mirrasoul J. Mousavi

Transformer fault detection and diagnosis is becoming more important due to the restructuring of the electric power industry. In this era of deregulation, loading transformers to their optimum capacity is becoming normal practice, which in turn applies high stresses on the insulation of the transformers and increases the probability of occurrence of internal incipient faults. Such faults can le...

2013
Salman Kahrobaee Marcelo C. Algrain Sohrab Asgarpoor

The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as high as ten times its rated current. This could cause many problems from mechanical stress on transformer windings to harmonics injection, and system protection malfunction. There h...

2013
Dan Zhou

The paper is concerned with transformer Weibull lifetime modelling which is recognised as essential for effective asset management within electric utilities. Two popular and widely adopted methods, maximum likelihood estimation and median rank regression, are discussed and compared for their properties in estimating transformer lifetime data. To greatly mimic the field collected transformer lif...

2012
Kapil Gandhi Yog Raj Sood

Power transformers use Kraft paper as insulation in the electrical windings present in the core, which is immersed in oil. In service, the temperature of the windings of core will go to 75C to 85C. If the transformer is over loaded, then the temperature can exceed upto 100°C causing the cellulose chains in the paper to cleave at an accelerated rate, which results in the degradation of mechanica...

2017
Ruohan Gong Jiangjun Ruan Jingzhou Chen Yu Quan Jian Wang Shuo Jin

This paper takes a typical 220 kV three-phase three-limb oil-immersed transformer as an example, this paper building transient field-circuit coupled model and 3D coupled magneto -fluid-thermal model. Considering a nonlinear B–H curve, the magneto model uses the field-circuit coupled finite element method (FEM) to calculate the magnetic flux distribution of the core and the current distribution ...

Journal: :Serbian Journal of Electrical Engineering 2019

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز 1387

چکیده ندارد.

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه علم و صنعت ایران - دانشکده مهندسی برق 1384

بطور کلی سیستم های تولید جریان بالا برای آزمایش تجهیزات قدرت (فیوزها، کلیدهای منیاتوری، کلیدهای اتومانیکو ...) کاربرد دارند. برای آزمایش رفتار و عملکرد تجهیزات قدرت تحت جریان های بالا، نیاز به تزریق جریان سینوسی است؛ به طوری که دامنه و فرکانس آن قابل کنترل باشد. در این پروژه دستگاه تزریق جریان، شامل یک ترانسفورماتور تزریق جریان است که توسط یک اینورتر منبع ولتاژ تغذیه می شود. هدف این پروژه، برر...

Journal: :The Journal of the Acoustical Society of America 1981

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید