نتایج جستجو برای: made hip prosthesis

تعداد نتایج: 556171  

Journal: :Collegium antropologicum 2001
I D Bajs V Sarić M Opalić

Following total hip arthroplasty the durability of a prosthetic implant depends on many factors but is generally limited by two types of damage: wearing of frictional surfaces of the acetabular and femoral component as well as the loosening and migration of the "rosthesis-cement-bone" system. Since it is possible to establish a cause-and-effect relationship between these two damage types, the a...

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

2014
Jong Hoon Kim Sung Kwang Chun Yong Cheol Yoon Devendra Lakhotia Won Yong Shon

PURPOSE In early prosthetic joint infection after hip arthroplasty, debridement with prosthesis retention may be performed for implant salvage, but the reported success rates are highly variable. Hence we reviewed the outcome of radical debridement and retention of prosthesis using established diagnostic criteria and surgical procedures in relation to significant variables including clinical ch...

2015

Objective: to characterize the epidemiological profile of patients undergoing hip replacement, primary or revisional. Methods: we conducted a retrospective, descriptive study, including hip arthroplasties performed from January 2009 to June 2012 in a Belo Horizonte teaching hospital, Minas Gerais State – MG, Brazil. Data were analyzed using descriptive statistics. Results: orthopedic procedures...

2016
Nora Renz Fabienne Chevaux Olivier Borens Andrej Trampuz

BACKGROUND Granulicatella and Abiotrophia spp. are difficult to detect due to their complex nutritional requirements. Infections with these organisms are associated with high treatment failure rates. We report the first implant-associated infection caused by Granulicatella para-adiacens, which was cured with anti-microbial treatment consisting of anti-biofilm-active rifampin and debridement, ex...

Journal: :Acta orthopaedica Belgica 2011
Bhavuk Garg Ravi Mittal Shishir Rastogi

Fracture of the femoral prosthesis neck following total hip arthroplasty is not common. We report a case of femoral prosthesis neck fracture in an adult male patient following modular, uncemented total hip arthroplasty. This case report further emphasizes the importance of the potentially high loading situation in the prosthetic femoral neck. On the other hand, the occurrence of a femoral prost...

Journal: :Collegium antropologicum 2007
Gordan Gulan Hari Jurdana

The Müller type cemented hip prosthesis, also called self-locking prosthesis, is one of the most extensively copied and utilized hip prostheses. Considering the implantation of the cemented stem, the author originally suggested achieving a press fit between the stem and endostal cortex by implanting a prosthesis of the largest possible size. Analyzing our group of patients who undergo aseptic s...

Journal: :Canadian Anaesthetists' Society journal 1974
K W Turnbull J L Berezowskyj J B Poulsen L S Root

TOTAL HIP REPLACEMENT has become a frequent procedure since the initial work of Charnley, McKee, Watson, Ferrar and Ring in the early 1960s. The most popular technique, that of Miiller, ~ involves a socket prosthesis fixed in the acetabulum with acrylic bone cement. A femoral prosthesis is then fixed in the medullary cavity with the same acrylic cement. Peroperative complications associated wit...

Journal: :Lancet 2014
Kirsten Dahms Yulia Sharkova Peter Heitland Sabine Pankuweit Juergen R Schaefer

574 www.thelancet.com Vol 383 February 8, 2014 In May, 2012, a 55-year-old man was referred to our clinic for severe heart failure (New York Heart Association class IV). He had raised brain natriuretic peptide of 1053 ng/L (normal <55 ng/L) and his estimated ejection fraction by echocardiography was 25%. His medical history was mostly uneventful, apart from the fact that he had had both hips re...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2003
C Liu S M Green N D Watkins P J Gregg A W McCaskie

A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemente...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید