نتایج جستجو برای: potentiometry ion selective membrane electrode

تعداد نتایج: 802881  

Journal: :international journal of nano dimension 0
sh. keyvan department of chemistry, faculty of science, islamic azad university, qeshm, iran. e. d. zobairi department of chemistry, faculty of science, islamic azad university, qeshm, iran. a. islamnezhad department of chemistry, faculty of science, islamic azad university, rasht, iran.

a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...

Hossein Naeimi Kobra Rabiei Mohammad Hossein Mashhadizadeh Mohammad Mazloum-Ardakani, Roya Mazidi

In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of  for perchlorate. The lim...

پایان نامه :دانشگاه تربیت معلم - تهران - دانشکده شیمی 1387

چکیده ندارد.

Forogh Adhami Leila Hajiaghababaei Saeid Takalou

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

Journal: :physical chemistry and electrochemistry 0

a pvc membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(iii) ion was prepared. this electrode revealedsuch a good selectivity toward la3+ ion over a wide variety of other metal ions. some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

H. Khanmohammadi H. Shafie M. Darvishpour M. H. Fekri R. Aminameli

A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشگاه پیام نور استان یزد - دانشگاه پیام نور مرکز اردکان - دانشکده علوم 1386

چکیده ندارد.

Hossein Aghaei Majjid Arvand Masood Giahi Mehran Aghaei

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید