نتایج جستجو برای: potentiometry ion selective membrane electrode
تعداد نتایج: 802881 فیلتر نتایج به سال:
a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
چکیده ندارد.
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
a pvc membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(iii) ion was prepared. this electrode revealedsuch a good selectivity toward la3+ ion over a wide variety of other metal ions. some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....
چکیده ندارد.
چکیده ندارد.
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید