نتایج جستجو برای: ray fluorescence analysis

تعداد نتایج: 3140408  

A. Mollahosseini, E. Noroozian H. Zahedi

According to circumstance of kerman sarcheshmeh cooper complex that its anode slime is mainly consisted of Cu, Ag, Au, Pb and Se. In this work, recovery of silver from anode slime and subsequent synthesis of silver nanoparticles from leaching solution was made. Silver was separated from anode slime by using of HNO3 and HCl. X-Ray fluorescence spectroscopy (XRF) was used to characterize anode sl...

Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 1998
E Brändström A Grzegorczyk L Jacobsson P Friberg A Lindahl M Aurell

BACKGROUND The aim of the present study was to compare the most commonly used GFR markers for clearance measurements, 51Cr-EDTA and iohexol, using two different methods for iohexol analysis, HPLC and X-ray fluorescence, referring both to the multiple-sample and single-sample calculations, using 51Cr-EDTA as the reference method. METHODS Forty-nine patients with an estimated GFR >40 ml/min wer...

2010
Yasuhiko Hayashi Fumio Okuyama

A new technical approach to breast-tumor detection is proposed. The technique is based on fluorescence x-ray analysis, and can identify a miniature malignant tumor within the breast. The primary beam intensity needed in fluorescence x-ray analysis is on a lower order of magnitude than that used in mammography. Thus, the newly-proposed technique would enable detection of a still tiny breast canc...

In this study, highly ordered mesoporous silica material (SBA-15) functionalized with Diethyl 2 - (9 -fluorenyl) malonate as a flourophore is reported. The anchoring of flourophores to the hydroxyl group on SBA-15 surface was done with post synthesis method. The obtained materials were characterized by small and wide angle X-ray diffraction, N2 adsorption–desorption, Fourier transform infrared ...

Journal: :international journal of nano dimension 0
a. hosseinian department of engineering science, faculty of engineering, university of tehran,tehran, iran. a.r. mahjoub department of chemistry, tarbiat modares university,tehran ,iran m. movahedi department of chemistry, payame noor university, isfahan, iran.

a new tris-chelate cd(ii) complex, [cd(dadmbtz)3](clo3)2 has been successfully synthesized and characterized by ir, 1h, 13c nmr spectroscopy, elemental analysis and single crystal x-ray determination. the thermal behavior, uv-vis and fluorescence spectra of compound were studied. in reaction with dadmbtz, cadmium (ii) forms a tris-chelate complex with nearly c3 symmetry for coordination polyhed...

Journal: :journal of mechanical research and application 2012
hamid khorsand nasim kiayee amir hossein masoomparast

in this study chemical method of dissolution-precipitation was applied to produce amorphous silica nanoparticles from rice straw ash (rsa), the waste material of rice cultivation. the morphology, particle size, structure and area of specific surface of synthesized amorphous silica nanoparticles were evaluated using transmission electron microscopy (tem), x-ray diffraction analysis (xrd) and bet...

Journal: :journal of physical & theoretical chemistry 2011
s. jalilehvand b. amirpour r. fazaeli m. h. givianrad a. mashinchian moradi

in this investigation we synthesized nax-nanozeolite by hydrothermal crystallization conditions.these nanoparticles were prepared at different conditions in a temperature controlled shaker. thesynthesized zeolites were characterized by instrumental analysis methods, such as x-raydiffraction (xrd), x-ray fluorescence (xrf), scanning electron microscopy (sem) andtransmission electron microscopy (...

2011

AMPTEK INC. 14 DeAngelo Drive, Bedford, MA 01730-2204 U.S.A. APPLICATIONS • X-Ray Fluorescence • Thin-film Analysis • RoHS/WEEE Analysis • Teaching and Research • Art and Archaeology • Process Control • X-ray Tube Characterization FEATURES • Fundamental parameters (FP) • Analysis with or without standards • General bulk and thin-film analysis • Analyze up to 40 elements • Supports all Amptek de...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید