نتایج جستجو برای: stereo radiography eos thermoluminescent dosimeter tld

تعداد نتایج: 43006  

2015
Emine Dilek Cakmak Nina Tuncel Bora Sindir

The aim of this study was to investigate the organ doses of patients undergoing computed tomography (CT) examination using the wide bore General Electric (GE) “Light Speed RT” unit. The head, chest and pelvic regions of the Rando-phantom were scanned with 120 kV, 200 mA, and 2.5 mm slice thickness for helical and axial modes. Thermoluminescent Dosimeter (TLD) pairs were used for the dosimetry o...

Journal: :Brachytherapy 2014
Argyris Moutsatsos Evaggelos Pantelis Panagiotis Papagiannis Dimos Baltas

PURPOSE To present experimental dosimetry results for the new IsoSeed I25.S17plus (125)I brachytherapy source, in fulfillment of the American Association of Physicists in Medicine recommendation for, at least one, experimental dosimetry characterization of new low-energy seeds before their clinical implementation. METHODS AND MATERIALS A batch of 100 LiF thermoluminescent dosimeter (TLD)-100 ...

2012
Kuang Hua Chu Yu Ting Lin Chia Chun Hsu Chien Yi Chen Lung Kwang Pan

This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective sim...

2007
Ana F. Maia Linda V.E. Caldas

Tandem systems formed with different thermoluminescent dosemeters were evaluated in standard diagnostic radiation beams. The utilized materials are commercially available, and the aim of this study was to carry out a performance comparison. The results show that the energy dependence of the materials, except TLD-100, were very high. Therefore, there are several possibilities of pair combination...

Ali Parach Fatollah Bouzarjomehri, Mahdieh Ghadimi Reza Nafisi Moghadam Seyed Mohammad Jalil Abrisham

Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...

Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

2015
Raffaele Liuzzi Federica Savino Vittoria D’Avino Mariagabriella Pugliese Laura Cella Gabriele Multhoff

BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...

2017
Mohmmadreza Aramesh Kobra Aria Zanganeh Masoud Dehdashtian Arash Malekian Jafar Fatahiasl

BACKGROUND This study aimed to evaluate the radiation dose received by premature neonates using diagnostic radiographies. METHODS This cross-sectional study was conducted on 116 premature neonates with gestational age from 25 to 37 weeks; with the diagnosis of neonatal respiratory distress syndrome (NRDS) and tachypnea, they were admitted to a neonatal intensive care unit (NICU) at Ahvaz Imam...

Journal: :International journal of radiation oncology, biology, physics 2012
J Lah D Kim S Park

PURPOSE To evaluate the suitability of the GD-301 glass dosimeter for use in in vivo dose verification in proton therapy. METHODS The glass dosimeter was analyzed for its dosimetric characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stair-like holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurement...