نتایج جستجو برای: bispectral index monitoring
تعداد نتایج: 681250 فیلتر نتایج به سال:
Justificativa e Objetivos A monitorização da profundidade da hipnose e da anestesia é um ato complexo. A maioria das propostas para monitorizar os níveis adequados da hipnose, durante a anestesia, envolve o EEG usando as ondas do EEG, ou mais recentemente, usando a forma processada. A análise bispectral é o método que permite analisar o EEG nas diferentes fases de freqüências. Conteúdo O EEG pr...
I report two patients undergoing open heart surgery, with nitrous oxide and isoflurane anaesthesia, for whom bispectral index (BIS) monitoring showed high BIS values with nitrous oxide and isoflurane anaesthesia. The BIS decreased immediately after nitrous oxide was stopped and increased again after nitrous oxide was restarted.
مقدمه: با توجه به کاربرد بالای بیهوشی عمومی در ایران در مقایسه با سایر روش های بیهوشی در جراحی سزارین و انتخاب آن از طرف خود مادران باردار، هدف این مطالعه، مقایسه ی تأثیر دو روش بیهوشی با پروپوفول و ایزوفلوران بر میزان بروز آگاهی حین عمل (awareness) و ضریب apgar نوزادان در جراحی سزارین انتخابی بود. روش ها: در این مطالعه ی کارآزمایی بالینی دوسوکور، تعداد 90 خانم باردار 35-18 ساله ی کاندید سزارین...
results seventy-five patients completed the study. compared to saline, patients who received 1 and 5 mg/kg of aminophylline demonstrated decreased extubation times (mean ± sd) (12.26 ± 7.33 vs. 11.15 ± 8.62 and 10.4 ± 4.78 min, respectively, p = 0.001) with higher bis values (p = 0.001). however, the recovery and discharge times from the pacu were no different between the aminophylline and sali...
Editor’s key points † Bispectral index (BIS) monitoring is commonly used to monitor depth of anaesthesia. † The authors studied parturients in whom standard techniques were used for general anaesthesia for Caesarean section. † The isolated forearm test was used to study the ability of the BIS to detect consciousness. † BIS values below 60 were commonly associated with IFT responses, particularl...
OBJECTIVE To identify the entropy levels that would correspond to bispectral index (BIS) levels in general anesthesia (GA) induction in patients who will undergo elective lumbar disc surgery (LDS). METHODS Thirty cases who underwent LDS under GA were included in our study after obtaining patient consent and approval of the Ethics Committee of Afyon Kocatepe University Medical School, Afyonkar...
BACKGROUND AND OBJECTIVE Both the bispectral and the patient state indices are derived from the electroencephalogram and have been proposed as a measure of the same clinical target, the hypnotic component of anaesthesia. The present study evaluated whether there is concordance between the bispectral and the patient state indices with regard to end-points measured simultaneously in patients unde...
Received: January 11, 2017 Revised: March 31, 2017 Accepted: April 01, 2017 Abstract: Background: Continuous cardiovascular monitoring as part of management of high-risk surgical patients is widely practiced, however the role of continuous monitoring as part of routine management in low-risk surgical patients is unclear. Our aim was to investigate haemodynamic and Bispectral Index (BIS) changes...
UNLABELLED Bispectral index (BIS) is an electroencephalographic variable promoted for measuring depth of anesthesia. Electromyographic activity influences surface electroencephalography and the calculation of BIS. In this study, we sought to determine the effect of spontaneous electromyographic activity on BIS. BIS was monitored in three volunteers by using an Aspect A-1000 monitor. The experim...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید