نتایج جستجو برای: bispectral index monitoring

تعداد نتایج: 681250  

2013
Jun Hyun Kim Ah Na Kim Kyung Woo Kim Sang-Il Lee Ji Yeon Kim Kyung-Tae Kim Jang Su Park Jung Won Kim Won Joo Choe

We report that intraoperative NIM-2 monitoring devices can interfere with bispectral index monitoring. A 45-year-old male with chronic otits media underwent tympanolasty under general anesthesia with NIM-2 monitoring and bispectral index monitoring at our institution. And then, bispectral index monitoring was severely interrupted by facial nerve monitoring.

2012
Heena Parikh Malini Mehta

Background: The use of clinical signs may not be reliable to measure the hypnotic component of anaesthesia. Bispectral Index monitoring provides a direct measurement of the hypnotic effect of the anaesthetic agent used and it may have certain clinical advantages over clinical signs. Objective: This study consists of dose requirement of propofol with bispectral Index monitoring and without bispe...

A.H. Chohedri E. Allahyari Reza Jouibar Sh. Shahbazi,

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

Journal: :European journal of anaesthesiology 2007
M Yamakage T Hayase J-I Satoh A Namiki

Pract Res Clin Anaesthesiol 2006; 20: 81–99. 3. Kin N, Konstadt SN, Sato K, Hanaoka K. Reduction of bispectral index value associated with clinically significant cerebral air embolism. J Cardiothorac Vasc Anesth 2004; 18: 82–84. 4. Hemmerling TM, Olivier JF, Basile F, Le N, Prieto I. Bispectral index as an indicator of cerebral hypoperfusion during off-pump coronary artery bypass grafting. Anes...

Journal: :anesthesiology and pain medicine 0
zahra faritous rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, iran arvin barzanji rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, iran rasoul azarfarin rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, iran behshid ghadrdoost rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, iran mohsen ziyaeifard rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, iran nahid aghdaei rajaie cardiovascular medical and research center, iran university of medical sciences, tehran, iran

conclusions it appears that bis monitoring can be used for pain assessment along with the cpot tool in intubated patients, and it is much more sensitive than monitoring of hemodynamic changes. bis monitoring can be used more efficiently in intubated patients under deep sedation in the icu. materials and methods seventy consecutive patients who underwent cardiac surgery (coronary artery bypass g...

Journal: :iranian journal of medical sciences 0
sh. shahbazi reza jouibar e. allahyari a.h. chohedri

background: inadequate depth of anesthesia leads to release of stress hormones. electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. the aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients.   methods: sevent...

Journal: :Best practice & research. Clinical anaesthesiology 2006
Jay W Johansen

Since 1997, bispectral index (BIS; Aspect Medical Systems Inc., Natick, MA) has been in clinical practice and a wealth of experimental research has accumulated on its use. Originally, the device was approved only for monitoring hypnosis and has now received an indication for reducing the incidence of intraoperative awareness during anesthesia. Numerous studies have documented the ability of BIS...

Journal: :European journal of anaesthesiology 2005
E Barrera S Fernández-Galinski E Arbonés F Escolano M M Puig

EDITOR: Several authors have reported sudden increases of the bispectral index values during different procedures such as endoscopic shoulder surgery [1], deep hypothermic circulatory arrest [2] or after using an upper-body blanket for warming [3]. In addition, spurious bispectral index values can be observed when the electromyogram activity of the bispectral index monitor reaches a value of 50...

Journal: :American journal of critical care : an official publication, American Association of Critical-Care Nurses 2012
Jaclyn M LeBlanc Joseph F Dasta Maria C Pruchnicki Anthony Gerlach Charles Cook

BACKGROUND Publications on the use of the bispectral index for sedation monitoring in the intensive care unit are increasing. However, few studies have involved correlation of bispectral index with serum drug concentrations. OBJECTIVES To assess the degree of correlation between bispectral index values, scores on the Sedation-Agitation Scale, and steady-state serum concentrations of lorazepam...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید