نتایج جستجو برای: bladder and rectum dose

تعداد نتایج: 16879822  

2016
Xianliang Wang Jie Li Pei Wang Ke Yuan Gang Yin Bin Wan

PURPOSE The purpose of this study was to demonstrate the dosimetric and clinical feasibility of image guided radiation therapy (IGRT) combined with high-dose-rate (HDR) intracavitary brachytherapy (ICBT) to improve dose distribution in cervical cancer treatment. MATERIAL AND METHODS For 42 cervical cancer patients, magnetic resonance imaging (MRI) scans were acquired after completion of whole...

2002
Miguel L. Rodríguez Carlos E. deAlmeida

Monte Carlo calculations of the absorbed dose at various points of a brachytherapy anthropomorphic phantom are presented. The phantom walls and internal structures are made of polymethylmethacrylate and its external shape was taken from a female Alderson phantom. A complete Fletcher-Green type applicator with the uterine tandem was fixed at the bottom of the phantom reproducing a typical geomet...

2017
Angelia Tran Jingjing Zhang Kaley Woods Victoria Yu Dan Nguyen Gary Gustafson Lane Rosen Ke Sheng

BACKGROUND Intensity-modulated proton therapy (IMPT), non-coplanar 4π intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate cancer treatment. METHODS Ten prostate patients were planned using IMPT with robustness optimizat...

2013
James C.L. Chow Runqing Jiang

This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric-modulated arc therapy (VMAT) using the single-arc technique. Dosimetry and radiobiological model comparison between the single-arc and double-arc prostate VMAT plans were performed on five patients with prostate volumes ranging from 29-68.1 cm3. The prescription do...

A Mesbahi, B Nasiri Motlagh H Ozan Tekin M Mohammadzadeh N Rasouli

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

2015
Antonio L. Damato Robert A. Cormack Akila N. Viswanathan

PURPOSE To investigate the dose distributions associated with a novel balloon sleeve placed over a standard cylinder applicator. MATERIAL AND METHODS A computed tomography (CT) scan of a sleeve balloon shaped to inflate into the vaginal fornices was used to digitize 1-, 3-, and 5-catheter configurations. Point doses for rectum, apex, and fornix were calculated and compared to the values assoc...

Journal: :Journal of radiation research 2010
Natsuo Tomita Hidetoshi Shimizu Takeshi Kodaira

The purpose of this study is to compare three-dimensional conformal radiotherapy (3D-CRT) plans in a setting of salvage radiotherapy after radical prostatectomy (RP) and to simulate whether dose escalation is possible with the most adequate 3D-CRT technique. This study included consecutive 10 patients underwent salvage radiotherapy (RT) for biochemical relapse of prostate cancer after RP. Norma...

2017
Noriyuki Kadoya YuYa Miyasaka Takaya Yamamoto Yoshihiro Kuroda Kengo Ito Mizuki Chiba Yujiro Nakajima Noriyoshi Takahashi Masaki Kubozono Rei Umezawa Suguru Dobashi Ken Takeda Keiichi Jingu

We evaluated dose-volume histogram (DVH) parameters based on deformable image registration (DIR) between brachytherapy (BT) and external beam radiotherapy (EBRT) that included a center-shielded (CS) plan. Eleven cervical cancer patients were treated with BT, and their pelvic and CS EBRT were studied. Planning CT images for EBRT and BT (except for the first BT, used as the reference image) were ...

2016
Jian Zhu Antoine Simon Pascal Haigron Caroline Lafond Oscar Acosta Huazhong Shu Joel Castelli Baosheng Li Renaud De Crevoisier

BACKGROUND To assess the benefits of bladder wall sub-volume equivalent uniform dose (EUD) constraints in prostate cancer intensity-modulated radiotherapy (IMRT) planning. METHODS Two IMRT plans, with and without EUD constraints on the bladder wall, were generated using beams that deliver 80 Gy to the prostate and 46 Gy to the seminal vesicles and were compared in 53 prostate cancer patients....

2006
Vitali Moiseenko Mitchell Liu Sarah Kristensen Gerald Gelowitz Eric Berthelet

In the present study, we aimed to evaluate effects of bladder filling on dose-volume distributions for bladder, rectum, planning target volume (PTV), and prostate in radiation therapy of prostate cancer. Patients (n = 21) were scanned with a full bladder, and after 1 hour, having been allowed to void, with an empty bladder. Radiotherapy plans were generated using a four-field box technique and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید