نتایج جستجو برای: concrete moment resisting frame

تعداد نتایج: 236522  

Journal: :IOP conference series 2021

Researchers awarded a considerable attention to progressive collapse analysis in recent years avoid the partial or entire failure of structures. General Service Administration guidelines (GSA) established base deal with such catastrophic failure. For multi-story building, these proposed column removal scenario which one more columns different locations should be removed from structure. Then, re...

Journal: :Engineering Structures 2022

SSI and site amplification effects are investigated as influences on the seismic fragility of existing reinforced concrete moment-resisting frame dual frame-wall system buildings supported shallow foundations without interconnecting beams. We build upon a holistic methodology that accounts for soil–foundation–structure interaction using modular approach. calculate curves based nonlinear dynamic...

In this study, the performance of triangular added damping and stiffness (TADAS) dampers combined with curved dampers (Curved-TADAS damper) is evaluated in moment resisting steel frame (MRSF). These dampers are passive and install in the beam-column connection region. Variable parameters of this study involve the width of curved damper (50, 75 and 100 mm), the thickness of TADAS damper (5 and 1...

Journal: :ce/papers 2022

This paper provides insight into a probabilistic demand analysis of steel-concrete structures equipped with novel dissipative components. DISSIPABLE components were studied in the framework European Research Fund for Coal and Steel (RFCS) project, funded to test large-scale which dissipation is concentrated specifically designed elements that act like fuse can easily be replaced after seismic e...

Journal: :Journal of Constructional Steel Research 2021

The work presented in this paper investigates the strength of moment-resisiting apex brackets cold-formed steel portal frames. results two previously reported full-scale frame tests, where frames failed through buckling bracket, were used to validate a finite element model that included material nonlinearity, geometric imperfections, and bolt bearing behaviour. From test as well results, import...

Moment resisting frames as one of the conventional lateral load resisting systems in buildings suffer from some limitations including code limitations on minimum span-to-depth ratio to ensure the formation of plastic hinges with adequate length at beam ends. According to seismic codes, in ordinary steel moment resisting frames the minimum span-to-depth ratios should be limited to 5 and in speci...

نمودار تعداد نتایج جستجو در هر سال