نتایج جستجو برای: glucose sensor
تعداد نتایج: 370589 فیلتر نتایج به سال:
BACKGROUND It has been generally accepted that the acute loss of sensor function is the consequence of sensor biofouling as a result of inflammation induced at sites of sensor implantation, as well as tissue trauma induced by the sensor and its implantation. Because anti-inflammatory therapies are used routinely to control inflammation in a wide variety of diseases, we hypothesized that anti-in...
It is generally accepted that unreliable in vivo performance of implantable glucose sensors originates, in large part, from tissue reactions to the implanted sensor, including foreign body reactions (i.e., inflammation, fibrosis, and vessel regression). Development of glucose sensor coatings with increased biocompatibility would contribute to the development of a reliable long-term glucose sens...
This paper presented a wearable microsystem including a microfluidic chip with an integrated threeelectrode electrochemical sensor for continuous glucose monitoring in subcutaneous interstitial fluid (ISF). The microfluidic chip fabricated by PDMS was used to transdermally extract ISF. The working electrode of the electrochemical sensor was modified by graphene and gold nanoparticles to improve...
BACKGROUND The accuracy and efficacy of the Medtronic Diabetes (Northridge, CA) Real-Time (RT)-Continuous Glucose Monitoring (CGM) sensor were analyzed in 72 subjects with type 1 diabetes. METHODS This was a retrospective analysis of 60,050 temporally paired data points (sensor and glucose meter values) obtained during the course of an outpatient ambulatory study evaluating the efficacy of a ...
abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...
a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...
OBJECTIVE There is no consensus on how to optimally assess the accuracy of continuous glucose sensors. We examined the continuous glucose-error grid analysis (CG-EGA) and compared it with classical accuracy assessment methods, using data from a previously reported study comparing two different continuous glucose sensors in type 1 diabetic patients. RESEARCH DESIGN AND METHODS Drift, delay, me...
Studies on tight glycemic control by intensive insulin therapy abruptly changed the climate of limited interest in the problem of hyperglycemia in critically ill patients and reopened the discussion on accuracy and reliability of glucose sensor devices. This article describes important components of blood glucose measurements and their interferences with the focus on the intensive care unit set...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید