نتایج جستجو برای: luminol
تعداد نتایج: 889 فیلتر نتایج به سال:
A novel flow-injection chemiluminescence(CL)method has been developed for the determination of hydroquinone (HQ) and catechol (CT), based on their inhibition of the chemiluminescence reaction of luminol–KMnO4–β-cyclodextrin (β-CD). It was found that β-cyclodextrin could effectively enhance the chemiluminescence produced from the reaction of luminol with KMnO4 in basic media. The proposed method...
Liposomes prepared with biotinylated phospholipids and luminol entrapped were shown to be of 187 nm in size, 59% of which were unilamellar and with 43% luminol trapping efficiency. Liposome prepared from biotinylated phospholipids with a longer hydrophilic PEG2000 spacer, but not with the shorter hydrophobic caproyl one, bound efficiently and specifically with immobilized streptavidin in a micr...
We proposed to combine an ultra-micro flow analysis instrument using the fused-silica capillary and the CL detector. The CL reaction of luminol and hydrogen peroxide was adopted and the batch-type CL detection cell was used. Luminol and isoluminol-labeled protein as a model were sensitively and reproducibly detected with very small amounts of quantitative reagents. The analyses were repeated at...
It was found that silver nanoparticles could strongly enhance the chemiluminescence (CL) of the luminol-KIO4 system in the presence of Co2+. The most intensive CL signals were obtained with silver nanoparticles in diameter of 22 nm. The studies of UV-visible spectra and CL spectra were carried out to explore the possible CL enhancement mechanism. Moreover, the influences of 17 amino acids and 2...
Fourteen derivatives of cinnamic and acrylic acids were evaluated for their ability to modulate chemiluminescence, evoked by neutrophils that had been exposed to luminol and phorbol-myristate-acetate. Compounds with one or two hydroxyl groups on the phenyl ring demonstrated significant inhibition of the chemiluminescence, but this inhibition was diminished by methoxylation. Saturation of the do...
BACKGROUND Different types of reactive oxygen metabolites (ROMs) are known to be involved in carcinogenesis. Several studies have emphasized the formation of ROMs in ischemic tissues and in cases of inflammation. The increased amounts of ROMs in tumor tissues can either be because of their causative effects or because they are produced by the tumor itself. Our study aimed to investigate and com...
This study includes determination Montelukast sodium by using flow injection chemiluminescence technique, the optimum concentrations were (150) ppm of magnesum ion, (5×10-4) M luminol, (0.001) hydrogen peroxide, linearity concetraction (0.1-0.001) that give highest luminescence intensity, and correlation cofficient was (0.9054), The relative standard deviation RSD% (2.3) detection limit (0.0001...
Based on the complexation between proteins and Cu(II) coupled with the time-resolved chemiluminescence (CL) technique, a highly sensitive and quantitative assay for measuring proteins in solution is described. The complexes of proteins with Cu(II) have a strongly catalytic effect on the luminol-H2O2 CL reaction. Because the CL emission produced by the complexes is much more long-lived than that...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید