نتایج جستجو برای: percent depth dose

تعداد نتایج: 559005  

2014
Alejandro Tormo Francisco Celada Silvia Rodriguez Rafael Botella Antonio Ballesta Michael Kasper Zoubir Ouhib Manuel Santos Jose Perez-Calatayud

PURPOSE Radiotherapy (RT) has played a significant role in treating non melanoma skin cancer (NMSC). High-dose-rate brachytherapy (HDR-BT) approaches have a paramount relevance due to their adaptability, patient protection, and variable dose fractionation schedules. Several innovative applicators have been introduced to the brachytherapy community. The Valencia applicator is a new superficial d...

Journal: :iranian journal of radiation research 0
b. azadbakht department of nuclear engineering, shiraz university, shiraz, iran m.h. zahmatkesh novin medical research institute, tehran, iran k. hadad department of nuclear engineering, shiraz university, shiraz, iran s. bagheri novin medical research institute, tehran, iran

background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...

2015
Christopher D. Johnstone Richard LaFontaine Yannick Poirier Mauro Tambasco

The purpose of this study was to empirically characterize and validate a kilovoltage (kV) X-ray beam source model of a superficial X-ray unit for relative dose calculations in water and assess the accuracy of the British Journal of Radiology Supplement 25 (BJR 25) percentage depth dose (PDD) data. We measured central axis PDDs and dose profiles using an Xstrahl 150 X-ray system. We also compare...

Journal: :journal of biomedical physics and engineering 0
f felfeliyan department of medical physics, school of medicine, isfahan university of medical sciences, isfahan, iran m atarod department of medical physics and radiology, shahrekord university of medical sciences, shahrekord, iran a amouheidari department of radiation oncology, milad hospital, isfahan, iran s noshadi department of medical physics, school of medicine, isfahan university of medical sciences, isfahan, iran p shokrani department of medical physics, school of medicine, isfahan university of medical sciences, isfahan, iran

background: field matching problems in abutting electron fields can be managed by using spoilers. objective: the aim of this study was to design a monte carlo framework for the assessment of spoiler application in abutting electron fields. methods: a siemens primus treatment head was simulated for a 5 mev electron beam using beamnrc and dosxyznrc, egsnrc user codes. validation of beam model was...

Journal: :iranian journal of radiation research 0
k. ghazi-khanlou sani department of radiology, hamadan university of medical sciences, hamadan, iran m. mohammadi department of medical physics, hamadan university of medical sciences, hamadan, iran a. eskandarlo department of radiology, hamadan university of medical sciences, hamadan, iran h. gholam-hosseinian department of radiotherapy, mash-had university of medical sciences, mash-had, iran

background: in conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. grid radiation therapy (grt) is a technique to deliver high doses, approximately 15 – 20 gy per fraction, to several small volumes located in a large radiation field. this can be performed using a grid block. the current work has concentrated on the ...

B. Azadbakht, k. Hadad, M.H. Zahmatkesh, S. Bagheri,

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان - دانشکده مهندسی عمران 1391

today, scouring is one of the important topics in the river and coastal engineering so that the most destruction in the bridges is occurred due to this phenomenon. whereas the bridges are assumed as the most important connecting structures in the communications roads in the country and their importance is doubled while floodwater, thus exact design and maintenance thereof is very crucial. f...

Journal: :Medical physics 2016
N Lamichhane M Studenski

PURPOSE It is essential to assess the lung dose during TBI to reduce toxicity. Here we characterize the accuracy of the AAA and Acuros algorithms when using cerrobend lung shielding blocks at an extended distance for TBI. METHODS We positioned a 30×30×30 cm3 solid water slab phantom at 400 cm SSD and measured PDDs (Exradin A12 and PTW parallel plate ion chambers). A 2 cm thick, 10×10 cm2 cerr...

A. Eskandarlo, H. Gholam-hosseinian, K. Ghazi-khanlou Sani, M. Mohammadi,

Background: In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 – 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work has concentrate...

ژورنال: سنجش و ایمنی پرتو 2015

In this research, a water calorimeter that can be used for dosimetry of electron beams from therapy accelerators at low absorption dose has been simulated using MCNP4C computer code. Then the depth dose curves were calculated and compared with experimental values. In addition, the effect of back scattering layers in depth of maximum dose was studied and it was found that these layers absorb the...

نمودار تعداد نتایج جستجو در هر سال