Ankita Sharma

With the rapid developments and use of non linear loads, the controlling over the harmonic current to get and maintain power quality is becoming more important. Active power filters has been used to compensate the harmonic pollution in our power system. This paper presents a efficient model to compensate the current harmonics using the inverter based Shunt Active Power Filter, Passive Power Fil...

2011
Brahim BERBAOUI Chellali BENACHAIBA

This work deals with the design, analysis and simulation of shunt active power filter SAPF, which compensate harmonic currents, and reactive power under balanced supply network. An optimal control theory for currents compensation based on particle swarm optimization is developed in this paper. The SAPF is connected in parallel with a nonlinear load which has caused current harmonics in industri...

2013
P. V. Ram Kumar M. Surya Kalavathi

Abstract: Shunt Active power filters (SAPF) technology has emerged nowadays as a very suitable option for power quality improvement in electrical power systems control. This paper presents the simulation study of a fuzzy logic hysteresis band current controlled, three-phase SAPF to enhance power quality by harmonic elimination, power-factor correction, reactive power compensation and balancing ...

2010
E. Latha Mercy R. Karthick S. Arumugam

Shunt Active Power Filters (SAPFs) represent the most important and widely used filter in industrial purposes due to the fact that, they not only eliminate the harmonic current with a neglected amount of active fundamental current supplied to compensate system losses, but also they are suitable for a wide range of power ratings. One of the key issues for a proper implementation of an active fil...

2015
Ming-Hung Chen

This paper proposes a new adaptive filter for wind generators that combines instantaneous reactive power compensation technology and current prediction controller, and therefore this system is characterized by low harmonic distortion, high power factor, and small DC-link voltage variations during load disturbances. The performance of the system was first simulated using MATLAB/Simulink, and the...

2010
G. SURESH BABU U. K. CHOUDHURY TULASI RAMDAS

Indian electrical industries supply alternators for rectifier loads, arc furnace loads and thyristor load applications to various customers. In such cases the generator line currents are not sinusoidal but are like trapezoidal which are due to harmonics .They may cause problems for utilities and industrial power system. Single tuned (ST) filter is the most commonly used device for both harmonic...

G. R. Yousefi and H. Seifi,

Load modeling is widely used in power system studies. Two types of modeling, namely, static and dynamic, are employed. The current industrial practice is the static modeling. Static modelss are algebraic equations of active and reactive power changes in terms of voltage and frequency deviations. In this paper, a component based on static modeling is employed in which the aggregate model is deri...

2014
M. Sharanya B. Basavaraja M. Sasikala

The power quality issues are of great concern now a days. The increasing use of power electronic devices based nonlinear loads deteriorate the quality of power. Power electronic appliances are widely used in industrial, commercial and utility system thus leading to various power quality problems. This leads to harmonics being injected into the distribution system and also reactive power burden....

Utilizing capacitor banks is very conventional in distribution network in order for local compensation of reactive power. This will be more important considering uncertainties including wind generation and loads uncertainty. Harmonics and non-linear loads are other challenges in power system which complicates the capacitor placement problem. Thus, uncertainty and network harmonics have been con...

G. R. Yousefi and H. Seifi,

Load modeling is widely used in power system studies. Two types of modeling, namely, static and dynamic, are employed. The current industrial practice is the static modeling. Static modelss are algebraic equations of active and reactive power changes in terms of voltage and frequency deviations. In this paper, a component based on static modeling is employed in which the aggregate model is deri...