نتایج جستجو برای: glass membrane electrode

تعداد نتایج: 516981  

Journal: :Journal of neural engineering 2014
J F Gómez-González A Destexhe T Bal

OBJECTIVE Electrophysiological recordings of single neurons in brain tissues are very common in neuroscience. Glass microelectrodes filled with an electrolyte are used to impale the cell membrane in order to record the membrane potential or to inject current. Their high resistance induces a high voltage drop when passing current and it is essential to correct the voltage measurements. In partic...

Journal: :journal of physical & theoretical chemistry 2009
m. zawari m. giahi h. aghaie

in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :The Journal of Pure and Applied Chemistry Research 2022

A tube type mini electrode has been made to detect paracetamol levels in herbal medicine, the is of a glass with diameter 0.7 cm, length 3 cm. As membrane mixture chitosan, activated carbon from rice husk, and cetyl trimethyl ammonium (CTA)-paracetamol. The internal solution standard 0.01 M phosphoric acid pH 2. average sensitivity sensor (22.60 ± 0.01) mV/decade linear concentration range 10-6...

Journal: :IEEE Trans. Instrumentation and Measurement 2001
Ger de Graaf Marian Bartek Zhixiong Xiao Cees J. van Mullem Reinoud F. Wolffenbuttel

Bulk micromachining in silicon and glass wafers and subsequent silicon-to-glass anodic bonding have been used for the realization of an electrostatic rms-to-dc converter. A suspended membrane has been designed for: large dynamic operating range (detection limit by minimum mechanical-thermal noise and high value of the pull-in voltage), maximum bandwidth (low series resistance, high second harmo...

Journal: :SIAM Journal of Applied Mathematics 2003
Ernest Puil Huaxiong Huang Robert M. Miura William P. Ireland

Deformation of glass using heat occurs in many industrial and artistic applications, including the manufacturing of laboratory glass products, drawing of fiber optics, and hand-blown artistic creations. The formation of glass objects is an art, but the trialand-error procedures can be reduced by development of a systematic theory, especially when the objects are formed using mechanical means. G...

Journal: :Nippon kagaku zassi 1950

Azin Azari Masoud Giahi Mohammad Ali Bagherinia

Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید