نتایج جستجو برای: 3d crt

تعداد نتایج: 195171  

2016
Malcolm D. Mattes Ying Zhou Sean L. Berry Christopher A. Barker

PURPOSE Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-C...

2014
Bradley M. Rauschenbach Luke Mackowiak Harish K. Malhotra

This study evaluates three-dimensional conformal radiotherapy (3D CRT), volumetric-modulated arc therapy (VMAT), and dynamic conformal arc therapy (DCAT) planning techniques using dosimetric indices from Radiation Therapy Oncology Group (RTOG) protocols 0236, 0813, and 0915 for the treatment of early-stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-fi...

2017
Rongqiang Pan Jingming Wang Feng Qi Ruizhen Liu

The aim of the study was to investigate the effect of three-dimensional conformal radiation therapy (3D-CRT) on nasopharyngeal carcinoma (NPC) and the incidence of complications. Between May 2010 and June 2012, 141 patients diagnosed with local recurrence of NPC due to cranial base lesions or cranial nerve symptoms, confirmed by pathology biopsy and/or by CT/MRI, were included in the present st...

2016
Masakuni Sakaguchi Toshiya Maebayashi Takuya Aizawa Naoya Ishibashi Shoko Fukushima Osamu Abe Tsutomu Saito

BACKGROUND Hypofractionated three-dimensional conformal radiation therapy (3D-CRT) is a treatment option for patients with early-stage non-small cell lung cancer (NSCLC) who are medically unable to tolerate surgery and who are not amenable to treatment with stereotactic body radiotherapy. This study assessed the efficacy and safety of 3D-CRT as a monotherapy in patients with localized stage T2 ...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2015
Aydin Cakir Zuleyha Akgun Merdan Fayda Fulya Agaoglu

Radiotherapy has an important role in the treatment of prostate cancer. Three-dimensional conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques are all applied for this purpose. However, the risk of secondary radiation-induced bladder cancer is significantly elevated in irradiated patients compared surgery-only ...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2011
Michael Pinkawa Nuria Escobar Corral Mariana Caffaro Marc D Piroth Richard Holy Victoria Djukic Gundula Otto Felix Schoth Michael J Eble

BACKGROUND AND PURPOSE The aim was to evaluate the impact of a spacer gel on the dose distribution, applying three-dimensional conformal (3D CRT) and intensity modulated radiotherapy (IMRT) planning techniques. MATERIAL AND METHODS The injection of a spacer gel (10 ml SpaceOAR™) was performed between the prostate and rectum under transrectal ultrasound guidance in 18 patients with prostate ca...

2013
Delphine Antoni Shanti Natarajan-Ame Philippe Meyer Claudine Niederst Khalil Bourahla Georges Noel

PURPOSE To analyze the outcome and dose distribution of intensity-modulated radiation therapy (IMRT) by helical tomotherapy in women treated for large supradiaphragmatic Hodgkin's disease. MATERIAL AND METHODS A total of 13 patients received adjuvant radiation at a dose of 30 Gy to the initially involved sites with a boost of 6 Gy to those areas suspected of harboring residual disease on the ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شهرکرد - دانشکده علوم ریاضی 1391

در این پایان نامه ابتدا به بررسی سیستم رمزی rsaوگونه ی سریعی از آن به نام crt-rsa می پردازیم. درسیستم رمزی crt-rsaمحاسبه رمزگشایی وامضا بااستفاده ازقضیه ی باقی مانده ی چینی ،crt،تسریع می شوند. همچنین حملات بر پایه ی اشتباه ،خطا،راتعریف کرده وبه بررسی این حملات روی سیستم رمزی crt-rsaمی پردازیم.اقدامات متقابل پیشین به خصوص اقدام متقابل شامیر در برابر حملات بر پایه اشتباه روی سیستم crt-rsa را مورد...

2017
Maxime Fournet Anne Bernard Sylvestre Marechaux Elena Galli Raphael Martins Philippe Mabo J. Claude Daubert Christophe Leclercq Alfredo Hernandez Erwan Donal

BACKGROUND Almost all attempts to improve patient selection for cardiac resynchronization therapy (CRT) using echo-derived indices have failed so far. We sought to assess: the performance of homemade software for the automatic quantification of integral 3D regional longitudinal strain curves exploring left ventricular (LV) mechanics and the potential value of this tool to predict CRT response. ...

C. Koksal, E.M. Fayda, H. Bilge, K. Ozkaya, M. Okutan, N.D. Kesen, S. Kucucuk, U. Akbas, U. Kalafat,

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید