نتایج جستجو برای: dose calculation

تعداد نتایج: 408802  

2014
Hideharu Miura Norihisa Masai Ryoong–Jin Oh Hiroya Shiomi Kouichi Yamada Junichi Sasaki Toshihiko Inoue

The purpose of this study was to investigate the impact of Monte Carlo (MC) calculations and optimized dose definitions in stereotactic body radiotherapy (SBRT) for lung cancer patients. We used a retrospective patient review and basic virtual phantom to determine dose prescriptions. Fifty-three patients underwent SBRT. A basic virtual phantom had a gross tumor volume (GTV) of 10.0 mm with equi...

Journal: :Physics in medicine and biology 2000
R Jeraj P Keall

The effect of the statistical uncertainty, or noise, in inverse treatment planning for intensity modulated radiotherapy (IMRT) based on Monte Carlo dose calculation was studied. Sets of Monte Carlo beamlets were calculated to give uncertainties at Dmax ranging from 0.2% to 4% for a lung tumour plan. The weights of these beamlets were optimized using a previously described procedure based on a s...

2015
Alexander Muacevic John R Adler David Roberge Claudie Leclerc-Champagne Robert Doucet Jan Seuntjens

BACKGROUND  In radiosurgery, the convention has been to prescribe radiation dose to a "covering isodose volume". This is presumed to be the minimum dose received by the entire tumor. Our purpose was to review our practice, assess different means of specifying a prescription isodose, and test how reliable they were in the face of various calculation methodologies. METHODS Different minimum dos...

Journal: :iranian journal of medical physics 0
hossein salehi yazdi m.sc. student of medical radiation engineering , nuclear engineering and physics dept., amirkabir university of technology, tehran, iran mojtaba shamsaei assistant professor, nuclear engineering and physics dept., amirkabir university of technology, tehran, iran hamid reza shabani m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran ramin jaberi radiotherapy physicist, cancer institute, imam khomeini hospital, tehran, iran saeed setayeshi associate professor, nuclear engineering and physics dept., amirkabir university of technology, tehran, iran

introduction: this study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (tps) for 192ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. materials and methods: a ct scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...

Journal: :journal of paramedical sciences 0
danial seifi makrani department of medical physics, faculty of medical sciences, semnan university of medical sciences, semnan, iran hadi hasanzadeh cancer research center, department of medical physics, semnan university of medical sciences, semnan, iran tayyeb allahverdi pourfallah department of biochemistry and biophysics, faculty of medicine, mazandaran university of medical sciences, sari, iran arash ghasemi department of radiology and radiation oncology, faculty of medicine, mazandaran university of medical sciences, sari, iran majid jadidi department of medical physics, faculty of medical sciences, semnan university of medical sciences, semnan, iran hamed babapour guilan oncology center (goc), rasht, iran

the monte carlo method can be used to describe any technique that approximates solutions to quantitative problems through statistical sampling. this method is considered to be the most accurate method for dose calculation in radiotherapy. for complete modeling of a linear accelerator, it is required that the manufactured information covers all data, but some data such as primary electron energy...

2012
Shimpei Hashimoto Katsuyuki Karasawa Yukio Fujita Hisayuki Miyashita Weishan Chang Toru Kawachi Tetsurou Katayose Nao Kobayashi Etsuo Kunieda Hidetoshi Saitoh

When a brass compensator is set in a treatment beam, beam hardening may take place. This variation of the energy spectrum may affect the accuracy of dose calculation by a treatment planning system and the results of dose measurement of brass compensator intensity modulated radiation therapy (IMRT). In addition, when X-rays pass the compensator, scattered photons are generated within the compens...

Ahad Ollah Ezzati, Hossein Mousavie Anijdan Seyed Rabi Mahdavi,

Introduction In this study, we aimed to calculate dose enhancement factor (DEF) for gold (Au) and iron (Fe) nanoparticles (NPs) in brachytherapy and teletherapy, using Monte Carlo (MC) method. Materials and Methods In this study, a new algorithm was introduced to calculate dose enhancement by AuNPs and FeNPs for Iridium-192 (Ir-192) brachytherapy and Cobalt-60 (Co-60) teletherapy sources, using...

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

Journal: :iranian journal of nuclear medicine 2003
kamal haddad mehrosadat alavi yeganeh gorji

determination of the total body absorbed dose consists of two parts: beta radiation absorbed dose and gamma radiation absorbed dose. the first part is generally determined by clinical data, while the second part has a parameter called absorbed ratio and is determined by computational methods. the monte-carlo computational methods have been shown to be the most suitable in determination of the a...

2002
Edward M. Reingold Nachum Dershowitz

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید