F. Haryanto, I. Arif, M.F. Rhani, R.C.X. Soh, S. Yani,

Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...

H. Saberi M. Momen Nezhad M. T. Bahreyni Toosi

Introduction:  Skin  sparing  is  one  of  the  most  desirable  characteristics  of  high  energy  photon  beams. However, the photons emerging from the target of linacs are contaminated by secondary  electrons  as  a  result  of  their  interactions  with  air,  collimators,  flattening  filter  and  any  other  objects in their path. This phenomenon tends to increase the skin dose received b...

Journal: :international journal of advanced biological and biomedical research 2015
mahdi jahangiri payman hejazi seyed mehdi hashemi abbass haghparast bardia hajizadeh

objective: using megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. the crucial problem for using photon beams >8mv is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. the contaminated neutrons produced in different components of the accelerator head and rely on many param...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :journal of medical signals and sensors 0
maryam atarod parvaneh shokrani

background: because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (at). in this study, the effect of maternal at and depth in fetal dosimetry was investigated, using peripheral dose (pd) distributio...

Ali Shabestani Monfared, Mohammad Davoudi Mohammad Rahgoshay

Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...

Ahad Zeinali Kamal Mostafanezhad Leila Mahani Milad Zeinali Kermani

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...

A Chairmadurai C Bhatt D Shrotiya L Chaudhari N Painuly, N Singh, T Verma

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه فردوسی مشهد 1376

in this thesis our aim is to construct vector field in r3 for which the corresponding one-dimensional maps have certain discontinuities. two kinds of vector fields are considered, the first the lorenz vector field, and the second originally introced here. the latter have chaotic behavior and motivate a class of one-parameter families of maps which have positive lyapunov exponents for an open in...