نتایج جستجو برای: Antimony determination

تعداد نتایج: 254588  

پایان نامه :0 1370

all analytical methods are generally based on the measurement of a parameter or parameters which are somehow related to the concentration of the species.an ideal analytical method is one in which the concentration of a species can be measured to a high degree precision and accuracy and with a high sensitivity. unfortunately finding such a method is very difficult or sometimes even impossible.in...

2006
Abbas Afkhami Tayyebeh Madrakian Azizeh Abdolmaleki

A method for rapid and accurate determination of trace quantities of SbIII was developed based on its inhibitory effect on the decolorizing reaction of methyl orange in the presence of bromate and bromide ions in acidic media. Decolorization of methyl orange by the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. The method allows determination of antimony in...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2003
mohammad ali taher

a highly selective, sensitive, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of antimony in various standard alloys and biological samples after adsorption of its 2-nitroso-1-naphthol-4-sulfonic acid - tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene in the ph range of 7.5-11.0. after filtration, t...

A highly selective, sensitive, rapid and economical differential pulse polarographic method has been developed for the determination of trace amounts of antimony in various standard alloys and biological samples after adsorption of its 2-nitroso-1-naphthol-4-sulfonic acid - tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene in the pH range of 7.5-11.0. After filtratio...

2003
Edwar Fuentes Ida De Gregori Martine Potin-Gautier

A sensitive atomic spectrometric method for the redox speciation analysis of antimony in soils is described. The method is based on the selective generation of stibine from Sb(III) in a continuous flow system using atomic fluorescence spectrometry for detection. Sb(V) is masked by citric or oxalic acid in HCl medium. The procedure was optimized with synthetic solutions of Sb(III) and Sb(V). The...

Journal: :The Analyst 2010
Shenguang Ge Congcong Zhang Yuanna Zhu Jinghua Yu Shuangshuang Zhang

A novel fluorescent nanosensor for Sb(3+) determination was reported based on thioglycolic acid (TGA)-capped CdTe quantum dot (QD) nanoparticles. It was the first antimony ion sensor using QD nanoparticles in a receptor-fluorophore system. The water-soluable TGA-capped CdTe QDs were prepared through a hydrothermal route, NaHTe was used as the Te precursor for CdTe QDs synthesis. Bovine serum al...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Sibel Saracoglu Mustafa Soylak Mehmet Dogan Latif Elci

The selective retention of the Sb(III) chelate with ammonium pyrrolidine dithiocarbamate (APDC) on a column of Chromosorb 102 resin from a buffered sample solution including Sb(V) was used for the determination of Sb(III). The retained antimony was eluted with acetone. The retention of the Sb(III)-iodide compounds with sodium iodide on the Chromosorb 102 resin column from the same solution afte...

Journal: :MMWR. Morbidity and mortality weekly report 2009
S Durgam

Antimony oxides, in combination with halogens, have been used as flame retardants in textiles since the 1960s. Uniforms made from fabric containing antimony are common among the estimated 1.1 million firefighters in the United States. In October 2008, CDC received a report from the fire chief of a fire department in Florida (fire department A) regarding an outbreak of antimony toxicity among 30...

2005
Huishi Guo Yiheng Li Xiaokang Chen Libo Nie Nongyue He

This work presents a sensitive method for the determination of trace antimony based on the antimony-pyrogallol red (PGR) adsorption at a carbon paste electrode (CPE). The optimal conditions were to use an electrode containing 25% paraffin oil and 75% high purity graphite powder as working electrode, a 0.10 mol/L HCl solution containing 3.0×10 mol/L PGR as accumulation medium and a 0.20 mol/L HC...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید