نتایج جستجو برای: Dose calculation Inhomogeneity phantom TiGRT

تعداد نتایج: 427787  

2016
Bagher Farhood Mohammad Taghi Bahreyni Toossi Shokouhozaman Soleymanifard

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

Journal: :iranian journal of medical physics 0
bagher farhood medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran mohammad taghi bahreyni toossi medical physics research center, mashhad university of medical sciences, mashhad, iran shokouhozaman soleymanifard medical physics research center, mashhad university of medical sciences, mashhad, iran

introduction wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (tps) is important. the objective ...

2017
Bagher Farhood Mohammad Taghi Bahreyni Toossi Shokouhozaman Soleymanifard Tohid Mortezazadeh

Aim of the study Our objective was to quantify the accuracy of dose calculation in the build-up region of the tangential field of the breast for a TiGRT treatment planning system (TPS). Material and methods Thermoluminescent dosimeter (TLD) chips were arranged in a RANDO phantom for the dose measurement. TiGRT TPS was also used for the dose calculation. Finally, confidence limit values were o...

2017
Daryoush Shahbazi-Gahrouei Mohsen Saeb Shahram Monadi Iraj Jabbari

BACKGROUND Performing audits play an important role in quality assurance program in radiation oncology. Among different algorithms, TiGRT is one of the common application software for dose calculation. This study aimed to clinical implications of TiGRT algorithm to measure dose and compared to calculated dose delivered to the patients for a variety of cases, with and without the presence of inh...

Shahram Monadi Vida rezaee,

Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 p...

Asghar Mesbahi, H. Dadgar,

Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS).  In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...

2016
Indra Yohannes Heru Prasetio Karoline Kallis Christoph Bert

We report an investigation on the accuracy of dose calculation based on the cone-beam computed tomography (CBCT) images of the nonbowtie filter kV imaging system of the Vero linear accelerator. Different sets of materials and tube voltages were employed to generate the Hounsfield unit lookup tables (HLUTs) for both CBCT and fan-beam CT (FBCT) systems. The HLUTs were then implemented for the dos...

Journal: :iranian journal of radiation research 0
m. mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia e. bezak

abstractbackground: although electronic portal imaging devices (epids) have originally developed for positioning verification, they can also be used for dosimetric purposes. in the current work, the dose response of minimum detectable thickness of a scanning liquid filled ion chamber epid, slic-epid, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was als...

2016
H. Dadgar

Background: Accurate dose calcula ons in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calcula on accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calcula ons. Materials and Methods: The head of Siemens Oncorimpression linac was simulated ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید