نتایج جستجو برای: Photon Contamination

تعداد نتایج: 123271  

آقامیری, محمودرضا , باغانی, حمیدرضا , حیدرلو, نعمت الله , مهدوی, ربیع ,

Background and purpose: Beam shaper is a type of applicator used in conjunction with the intraoperative electron radiotherapy. This study aimed at quantitative evaluation of the photon contamination of this applicator using Monte Carlo simulation. Materials and methods: In this experimental study, at first the head of LIAC accelerator was simulated along with the beam shaper applicator using...

Journal: :iranian journal of medical physics 0
nasrollah jabbari assistant professor, medical imaging dept., urmia university of medical sciences, urmia, iran. bijan hashemi associate professor, medical physics dept., tarbiat modarres university, tehran, iran.

introduction: in clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. this bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

H Gholamhosseinian M Behmadi M Mohammadi, M Momennezhad, M T Bahreyni Toossi, Sh Bayani Sh Naseri,

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

Journal: :journal of biomedical physics and engineering 0
m robatjazi tehran university of medical sciences k tanha bushehr university of medical sciences s r mahdavi iran university of medical sciences h r baghani shahid beheshti university h r mirzaei shahid beheshti university of medical sciences m mousavi tehran university of medical sciences

background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated a...

Journal: :iranian journal of radiation research 0
a. mesbahi department of medical physics, medical school, tabriz university of medical sciences, tabriz, iran p. mehnati department of medical physics, medical school, tabriz university of medical sciences, tabriz, iran a. keshtkar department of medical physics, medical school, tabriz university of medical sciences, tabriz, iran

background: monte carlo method (mc) has played an important role in design and optimization of medical linacs head and beam modeling. the purpose of this study was to compare photon beam features of two commercial linacs, varian 21ex and elekta sl-25 using mcnp4c mc code. materials and methods: the 6mv photon beams of varian 21ex and elekta sl-25 linacs were simulated based on manufacturers pro...

Khadijeh Hosseini Nahid Chegeni

  Introduction: Several studies have discussed to the electron contamination caused by the air column between the head of linac and patient for photon beams. Since it is not possible to measure the electron contamination with practical dosimetry, the Monte Carlo technique is an appropriate and accurate choice to calculate particle flounce in radiation therapy. The purpose of t...

A. Keshtkar, A. Mesbahi, P. Mehnati,

Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...

Journal: :iranian journal of radiation research 0
m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. zabihzadeh department of medical physics, jondishapour university of medical sciences, ahvaz, iran m.r. ay department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran s.r. mahdavi department of medical physics, iran university of medical sciences, tehran, iran m. shahriari department of nuclear engineering, shahid beheshti university, tehran, iran a. mesbahi department of medical physics, tabriz university of medical sciences, tabriz, iran

background: the electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. the detailed characteristics of contaminant electrons are presented for different field sizes and cases. materials and methods: the monte carlo code, mcnpx, has been used to simulate 18 mv photon beam from a varian linac-2300 accelerator. all dose measurements were carried out u...

Journal: :international journal of advanced biological and biomedical research 2015
mahdi jahangiri payman hejazi seyed mehdi hashemi abbass haghparast bardia hajizadeh

objective: using megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. the crucial problem for using photon beams >8mv is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. the contaminated neutrons produced in different components of the accelerator head and rely on many param...

Hojatollah Shahbazian Jafar Fatahiasl Mansour Zabihzadeh Mohammad Ali Behrooz Mohammad Javad Tahmasebibirgani Nahid Chegeni Reza Maskani

Introduction: Photon contamination is a restriction on treatment with electron that increase dose to healthy tissue below the tumor. The aim of this study is to reduce the photon contamination using a magnet system. Materials and Methods: A mini-applicator equipped with two neodymium boron permanent magnets was designed which make it possible to adjust the d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید