Journal: :Journal of clinical microbiology 2002
Pascale Bemer Frantiska Palicova Sabine Rüsch-Gerdes Henri B Drugeon Gaby E Pfyffer

The reliability of the BACTEC Mycobacteria Growth Indicator Tube (MGIT) 960 system for testing of Mycobacterium tuberculosis susceptibility to the three front-line drugs (isoniazid [INH], rifampin [RIF], and ethambutol [EMB]) plus streptomycin (STR) was compared to that of the BACTEC 460 TB system. The proportion method was used to resolve discrepant results by an independent arbiter. One hundr...

Journal: :Journal of infection in developing countries 2008
Jacob Otu Martin Antonio Yin Bun Cheung Simon Donkor Bouke C De Jong Tumani Corrah Richard A Adegbola

BACKGROUND The BACTEC MGIT 960 was evaluated and compared with BACTEC 9000 MB and Lowenstein-Jensen medium for recovery rate of mycobacteria, time to detection, and contamination rate. METHODOLOGY 147 sputum samples obtained from patients with suspicion of tuberculosis were processed and inoculated into BACTEC MGIT 960, BACTEC 9000 MB and Lowenstein-Jensen medium using standardized procedures...

مقایسه محیط کشت لوین – اشتاین (L.J) و ویالهای رادیومتریک (BACTEC-128) با لوله نشان دهنده رشد مایکوباکتریوم (MGIT) در تشخیص سل.156 بیمار مشکوک به سل و 40 نفر شاهد در مرکز آموزشی، پژوهشی و درمانی سل و بیماریهای ریوی تحت بررسی قرار گرفتند. 0.5 میلی لیتر هموژن بدست آمده از خلط بیماران به محیط کشت لوین – اشتاین، ویالهای BACTEC-12B و لوله های MGIT تلقیح و در 37C برای 4 هفته نگهداری شد. لوله های BACTE...

Journal: :Annals of clinical and laboratory science 2001
T S Huang C S Chen S S Lee W K Huang Y C Liu

The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid detection of mycobacteria in clinical specimens was evaluated and compared to the radiometric method (BACTEC 460TB) and to mycobacterial culture on Lowenstein-Jensen (LJ) medium. Clinical specimens (n = 590) were tested without selection. A total of 121 (20.5%) isolates of mycobacteria were recovered; 98 (81.0...

Journal: :The Malaysian journal of pathology 2004
R Ganeswrie C S Chui S Balan S D Puthucheary

This study was carried out to compare the performance of BACTEC MGIT 960 with the BACTEC 460 TB for growth and detection of Mycobacteria from human clinical specimens. The BACTEC MGIT 960 instrument is a fully automated system that utilizes MGIT tubes containing an oxygen sensor embedded in silicon at the bottom and filled with 7 mL of modified Middlebrook 7H9 broth. Identical samples were inoc...

Journal: :Journal of clinical microbiology 1998
P R Murray G E Hollick R C Jerris M L Wilson

The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception of Str...

Journal: :Journal of clinical microbiology 1983
N M Burdash J P Manos E R Bannister A L Welborn

To determine whether acridine orange (AO) staining of blood cultures could be used as a substitute for blind subculture when used in conjunction with the BACTEC system (Johnston Laboratories, Inc., Towson, Md.), the two methods were compared on all BACTEC-negative specimens. Since blind subcultures were routinely performed in our laboratory on days 2 and 6 of incubation, AO staining was also pe...

Journal: :Journal of clinical microbiology 1999
E Tortoli P Cichero C Piersimoni M T Simonetti G Gesu D Nista

The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automa...

Journal: :Journal of clinical microbiology 2015
Hao Shen Jin Tang Qiaojie Wang Yao Jiang Xianlong Zhang

Prosthetic joint infection (PJI) is a rare but refractory complication of arthroplasty. Accurate identification of pathogens is a key step for successful treatment of PJI, which remains a challenge for clinicians and laboratory workers. We designed a combined culture method with sonication of implants and incubation in a BD Bactec system to improve the effectiveness of pathogen diagnosis in PJI...

Journal: :Journal of clinical microbiology 2002
Gaby E Pfyffer Frantiska Palicova Sabine Rüsch-Gerdes

The reliability of the novel BACTEC MGIT 960 pyrazinamide (PZA) kit (Becton Dickinson Microbiology Systems, Sparks, Md.) was assessed for testing of susceptibility of Mycobacterium tuberculosis to PZA. Results generated by the BACTEC MGIT 960 system (Becton Dickinson) were compared with those obtained with the BACTEC 460TB system. Extensive proficiency testing (phase I) and reproducibility test...